EUROSTER Q7TXRX
GW
–
INSTALLATION AND OPERATION MANUAL
16
b.
NUMBER OF TX
–
selecting from 1 to 6 determines how many thermostats will operate
with one RX module
Setting a value of 1 enables operation with several RX modules. NUMBER OF RX option is
available.
Setting a value of 2 or more disables the NUMBER OF RX option and requires establishing
the switching on and off priorities for the thermostats. The following additional options are
available:
TURN ON IF
–
determining which thermostats should switch the heating device on and
when.
•
EACH
–
switching the heating device on when the temperature at each of the selected
thermostats drops below the set point (an equivalent of the serial connection of wired
thermostats).
•
ANY
–
switching the heating device on when the temperature at any of the selected
thermostats drops below the set point (an equivalent of the parallel connection of
wired thermostats).
TURN OFF IF
–
determining which thermostats should switch the heating device off and
when.
•
EACH
–
switching the heating device off when the preset temperature is reached at
each of the selected thermostats (an equivalent of the parallel connection).
•
ANY
–
switching the heating device off when the preset temperature is reached at
any of the selected thermostats (an equivalent of the serial connection).
The priorities of switching on or off are selected with the knob by turning it to select the
proper no. in the EACH or ANY item. Any, but only one, of these options may be assigned to
switching the device on and one to switching it off.
E.g. when
turn on if
–
each
is set and only no. 3 is selected, then the receiver will only
switch on the heating device if the temperature drops below the preset one in the three
rooms with thermostats no. 1, 2 and 3.
When
turn off if
–
any
is set and no. 4 is selected, then the receiver will switch on the
heating if the preset temperature is reached at least at one of thermostats no. 1, 2, 3 or 4,
even if it will not be reached at the other ones.
Usually the priorities are set as in standard wired connections: the serial one (turn on if:
each
–
turn off if: any) or the parallel one (turn on if: any
–
turn off if: each). It is also
possible to set the priorities that are impossible in simple wired connection: EACH for
switching on and EACH for switching off with the selection of all paired thermostats. It is also
possible to set a number for switching on and a different one for switching off. Then, all
others are not involved in switching on or off. Please remember that switching off is superior
to switching on. If ANY is set for the switch off along with a number greater than for the
switch on, then regardless of the priority (each or any) set for the switch on, all thermostats
must require heating in order to make the receiver switching the device on.
It is possible to introduce settings enabling switching the heating on only when the
temperature at all thermostats will be lower and switching it off when the temperature will
be reached at the first one only (switch on if: each 6
–
switch off if: each 1). It is also
possible to introduce settings enabling only the first thermostat to switch the heating on and
switch it off only when the temperature raises at all thermostats (switch on: each 1
–
switch
off: each 6). Should you experience any problems with setting priorities we recommend
contacting our service.
c.
NUMBER OF RX
–
selecting from 1 to 6 determines how many receivers will cooperate
with one thermostat
The receivers will simultaneously switch the connected devices on and off.