8. SAFETY CARD RUNNING (continued)
8.5. THE FOUR LAMPS ARE LIGHTED OFF
Défaut
A vérifier
Remèdes
Electric problem
No motor contact
Turn the motor key
Emergency stop on the hood is pres-
sed
Unlock emergency stop
The circuit breaker is not engaged
Control the circuit breaker position,
turn the key in clockwise direction .
The fuse of the control panel is out of
order
Change the fuse
Battery connections are wrong
Control the 2 battery pods . Check the
presence of verdigris, brush the pods .
Battery is out of order or has a lack of
charge
Contact the nearest technical service,
the battery must be changed . Pay
attention to polarity
Electric supply circuit must be cut
somewhere
Contact your technical service
Protection fuses of the card
Change the defective fuse