201902-340-ENG
User manual - COMPACT-PRO 60 & 80
P21
7. FAILURES AND REMEDIES (continued)
n°
Faliure
To check
Remedy
10
The hopper screw does not stop
when the air to the lance is closed
Check the waterproofness of the
air hose and
connectors .
There must be no air
leakage on the circuit .
Check the connections on the
pressure switch .
Remove any air leakage on the
connector .
Check the vacuum valve does
not leak .
Contact your technical service .
Check the compressor belt
tense .
Retense the compressor belt .
Hydraulic problem .
Contact your technical service .
11
The product does not flow at the
projection lance
Check there is no plug in the
product hoses .
Check the product consistancy /
Unplug the hoses .
Mortar or lime projection
Check you have added a
plasticizer in your product
preparation .
Check the valve on the
projection lance .
It must be open
Check that the hopper screw is
turning well
See problem n° 9
Check the pump wear
Use the pressure
controller at the pump exit
12
Check your water supply
The hose must not be pinched
and the water valve must be
open .
Check the filter clogging
Clean the supply filter before any
use
Hydraulic problem
Contact the nearest
dealer .
Summary of Contents for COMPACT-PRO 60
Page 2: ...User manual COMPACT PRO 60 80 201902 340 ENG P2 ...
Page 26: ...User manual COMPACT PRO 60 80 201902 340 ENG P26 ...
Page 27: ...201902 340 ENG User manual COMPACT PRO 60 80 P27 ...
Page 28: ...User manual COMPACT PRO 60 80 201902 340 ENG P28 ...
Page 30: ...User manual COMPACT PRO 60 80 201902 340 ENG P30 ...
Page 31: ...201902 340 ENG User manual COMPACT PRO 60 80 P31 ...
Page 32: ...User manual COMPACT PRO 60 80 201902 340 ENG P32 ...