System Manual Safety System MGB-AR in Combination with a Locking Module
6
Troubleshooting
Latching fault when actuating the escape release
In order to achieve monitoring of the locking device in category 4, PL e according
to EN ISO 1849-1, an internal monitoring logic system is integrated into every
locking module.
Result:
: The MGB system enters into a latching fault when the escape release is
actuated (see
System status table
on page ).
Note!
The system might not enter into a latching fault if the escape release is actuated
very slowly.
Fault reset
Proceed as follows:
Open the safety guard.
Switch the operating voltage off at the locking module for min. seconds.
As an alternative, 4 V can be applied to the input RST for min. seconds.
The green LED (DIA1) flashes quickly (approx. 10 Hz). A self-test is performed
during this time (approx. 8 s). The LED then cyclically flashes three times.
Close safety guard and switch guard locking on.
The system is in normal mode again.
1.
.
.
Guar
d position
Bolt tongue posi
-
tion
Guar
d locking
Safety outputs OA and OB
Door monitoring output
Bolt tongue moni
-
toring output
Guar
d locking
monitoring output
Monitoring output DIA 2
LED display
State
DIA 1 (gr
een)
POWER
DIA 2 (r
ed)
ST
ATE (yel
-
low)
X
X
X
off
off
off
off
on
6 x
Signal sequence erroneous
Key
LED is not lit
LED is lit
x
LED flashes three times
X
Any state