System Manual Safety System MGB-AR in Combination with a Locking Module
1
3 mm
9
10
OPEN
CLOSED
9
Undo setscrew.
AT
Move door handle 90° clockwise and fasten
again.
Tighten setscrew to Nm
AK
State after the change
Fig. 13: Changing actuating direction, step
9
and
AT
Figure 14: Changing actuating direction, final state
Protection Against Environmental Effects
Lasting and correct safety function requires that the system must be protected
against foreign bodies such as swarf, sand, blasting shot, etc. which can become
lodged in the locking and handle modules. For this purpose a suitable installation
position should be selected.
Cover device during painting work!