![EUCHNER MGB-AR Series System Manual Download Page 24](http://html.mh-extra.com/html/euchner/mgb-ar-series/mgb-ar-series_system-manual_2434730024.webp)
System Manual Safety System MGB-AR in Combination with a Locking Module
4
Technical Data
Note!
If a product data sheet is included with the product, the information on the data
sheet applies in case of discrepancies with the operating instructions.
Parameter
Value
Unit
Housing material
Glass fiber reinforced plastic
die-cast zinc, nickel-plated
Stainless steel
Dimensions
See dimension drawing
Weight
Locking module
Handle module
Escape release
0,75
1,00
0,50
kg
Ambient temperature at U
B
= DC 4 V
-0 .... +55
°C
Degree of protection
- on usage of key-operated switches
IP 54
IP 4
Safety class
III
Degree of contamination
Installation position
Any
Locking force F
zh
according to GS-ET-19
000
N
Connection type
4 cable entries M0x1.5 or plug connector RC18
Conductor cross-section (rigid/flexible)
- with ferrule according to DIN 468/1
- with ferrule with collar according to DIN 468/1
0.1 ... 1.5 (AWG 4 ... AWG 16)
0.5 ... 1.5
0.5 ... 0.75
mm²
Operating voltage U
B
(reverse polarity protected, regulated, residual
ripple < 5 %)
4 +10% / -15% (PELV)
V DC
Auxiliary voltage U
A
(reverse polarity protected, regulated, residual
ripple < 5 %)
4 +10% / -15% (PELV)
V DC
Current consumption I
UB
(no load on any outputs)
80
mA
Current draw with interlocking solenoid I
UA
(with
energized interlocking solenoid and unloaded
outputs O1 ... O4)
50
mA
-
Additional current consumption for version with
controls and indicators in the cover
Max. 0
mA
External fuse
See page 16 "Fuse protection for power supply"
Safety outputs OA/OB
Semiconductor outputs, p-switching, short
circuit-proof
Output voltage U
OA
/U
OB
1)
HIGH
U
OA
/ U
OB
U
B
-V ... U
B
LOW
U
OA
/ U
OB
0 ... 1
V DC
Switching current per safety output
1 ... 00
mA
Utilization category according to EN IEC 60947-
5-
DC-1 4 V 00 mA
Caution: outputs must be protected with a free-
wheeling diode in case of inductive loads.
Classification acc. to EN IEC 60947-5-
PDF-M
Monitoring outputs
- Output voltage
1)
- Max. load
p-switching, short circuit-proof
U
A
- V ... U
A
Max. 00
mA
Rated insulation voltage U
i
0
V
Rated impulse withstand voltage U
imp
1,5
kV
Resilience to vibration
As per EN IEC 60947-5-
Switching frequency
1
Hz
EMC protection requirements
As per EN IEC 60947-5-
Reliability figures according to EN ISO
13849-1
Category
4
Performance Level
PL e
PFH
d
.4 x 10
-9
/ h
)
Mission time
0
years
1) Values at a switching current of 50 mA without taking into account the cable lengths.
) Applying the limit value from EN ISO 1849-1:008, section 4.5. (MTTF
d
= max. 100 years), BG certifies a PFH
d
of max.
.47 x 10
-8
.