7.2. Safety distance, light curtains (vertical mounting)
For vertical mounting, first the resolution of the device is to be determined.
Depending on the result, a differentiation is made between two cases:
Case A: Resolution ≥ 50 mm
Case B: Resolution < 50 mm
The related section is to be followed depending on the result.
TIP
You will find the resolution of the device in chapter 11: Technical data
Case A: Resolution ≥ 50 mm
The safety distance S is calculated using the following formula:
S
=
1600
(t1
+
t2)
+
850
Important!
The following distances are to be maintained during the calculation:
Ì
Distance surface of the floor (G) – first light beam = H1 max. 300 mm
Ì
Distance surface of the floor (G) – last light beam = H2 max. 900 mm
G
Reference floor (G)
S
Hazardous point
Direction
of approach
Light curtain
H
≥
900
H
≤
300
Figure 10: Vertical mounting for light curtains with resolution from 50 mm