7. Mounting
Transmitter and receiver must be positioned while maintaining the minimum safety distance S. It is only allowed to be possi-
ble to reach the danger area after stopping the hazardous machine movement (see Figure 8 ). The safety distance for light
grids and light curtains must be calculated as per the following chapter.
Figure 8:
Safety distance S
The minimum safety distance S is calculated based on the following formula:
S
=
K
(t1
+
t2)
+
C
C
=
8
(d
–
14)
Variable
Definition
S
Minimum safety distance [mm] is given by the distance between
the start of the detection area and the start of the danger area
K
Approach speed of the body in the danger area [mm/s]
t1
Total reaction time for the item of electro-sensitive protective equipment in seconds [s]
t2
Reaction time of the machine in seconds; this is the time the machine requires to interrupt the dangerous process after a signal stop [s]
C
Additional distance that varies depending on the application [mm]
1)
d
Resolution [mm]
1) For further information in relation to the additional distance, see EN 13855:2010
Important!
Ì
The minimum safety distance must be maintained because otherwise the protective function of the
device will not be ensured.
Ì
If it is possible to access the danger area without interrupting the protective field, a movable safe-
ty guard is to be provided in addition.