Specifications
MODEL 2081 TURNTABLE SERIES
24
© ETS-LINDGREN L.P. – JANUARY 2003
REV D – PN 399212
SPECIFICATIONS
ELECTRICAL
Model Drive
Speeds
RPM
Voltage
Line
Frequency
AMP Phase
2081-2.0 Series
Dual .5/2.0
208-230 60
8 3
Dual .5/2.0 380
50
5 3
Variable .5/2.0 208-230
60
18
3
Variable .5/2.0
380
50
7
3
2081-3.0 Series
Dual .5/2.0
208-230 60
8 3
Dual .5/2.0 380
50
5 3
Variable .5/2.0 208-230
60
18
3
Variable .5/2.0
380
50
7
3
Variable .5/2.0 208-230 50/60
15 Single
2081-4.0 Series
Dual .5/2.0
208-230 60
8 3
Dual .5/2.0 380
50
5 3
Variable .5/2.0 208-230
60
18
3
Variable .5/2.0
380
50
7
3
Variable .5/2.0 208-230 50/60
15 Single
2081-5.0 Series
Dual .5/2.0
208-230 60 13 3
Dual .5/2.0 380
50
8 3
Variable .5/2.0 208-230
60
20
3
Variable .5/2.0
380
50
14
3
2081-6.0 Series
Dual .5/2.0
208-230 60 13 3
Dual .5/2.0 380
50
8 3
Variable .5/2.0 208-230
60
20
3
Variable .5/2.0
380
50
14
3
PHYSICAL
Model Diameter Nominal
Height
Distributed
Load
Rating*
Top Construction
2081-2.0 Series
2.0 m
6.56 ft
40.0 cm
15.75 in
1,500 kg
3,300 lb
Sectional
Aluminum
2081-3.0 Series
3.0 m
9.84 ft
40.0 cm
15.75 in
4,000 kg
8,800 lb
Sectional
Aluminum
2081-4.0 Series
4.0 m
13.12 ft
40.0 cm
15.75 in
6,000 kg
13,200 lb
Sectional
Aluminum
2081-5.0 Series
5.0 m
16.40 ft
40.0 cm
15.75 in
6,800 kg
15,000 lb
Sectional
Aluminum
2081-6.0 Series
6.0 m
19.69 ft
40.0 cm
15.75 in
9,000 kg
20,000 lb
Sectional
Aluminum
*Distributed Load Rating is based on load being evenly distributed to each section. No point loads under
.37 sq. m (4 sq. ft) should exceed 500kg (1100 lb); and not over 500 kg should be applied to a 45 degree
segment outboard of the casters.
Archived 3/18/10