INSTALLATION
The installation of turntables 2 meters and larger will be performed
by a factory installation specialist or by individuals who have been
authorized by ETS-Lindgren to do such work. Proper installation
of the turntable directly affects performance. The following
installation information is provided to familiarize the user of the
turntable with the installation process.
1.
Uncrate all parts.
NOTE:
Do not discard any packing material
until unit is fully assembled. Check all parts for any shipping
damage. Ensure a clear area is available to assemble the
turntable unit safely.
2.
After removing three ½-13 flat head screws from the center of
the turntable, install three eye-bolts (provided) for lifting the
turntable center drive section.
3.
Attach lifting chains or slings though the eye-bolts.
CAUTION
Lifting and placement of turntable center drive unit
into a pit should only be performed by qualified personnel.
4.
Safely lift the turntable into the pit using a forklift or other
appropriate lifting device, place the turntable bottom or bearing
support section into position.
5.
Remove the drive pinion so the turntable may be rotated
manually.
6.
If the turntable is to be installed into a pit or floor cut-out,
center and level the assembly. The drawings at the back of this
manual illustrate the placement of floor plates and leveling
screws that will take place in order to anchor and level the
turntable. Your installation specialist may have to make slight
adjustments to accommodate the conditions at your site. After
installing the floor plates and leveling screws the installer will
level the entire turntable by adjusting all the leveling screws.
CAUTION
Ensure power is OFF and secured before proceeding
further.