MAINTENANCE
49
For fine calibration:
1. Complete coarse calibration.
2. Using strobe tach measure asphalt pump shaft speed in RPM.
3. Multiply RPM by 0.61 to get calculated GPM.
4. Turn calibration until calculated GPM matches pump tach.
For coarse calibration:
Instructions for calibrating pump speed for units
with 309 pulses per gallon only (hydraulic motor
#6603157 with 4.39 to 1 ratio gearbox).
3
Hex Wrench
Remove wrench
and reinsert with
wrench leg
directly on top of
mounting thread.
4
Hex Wrench
Turn calibration
counterclockwise
until parallel with
both mounting
threads.
Setting
“8”
1
Select setting 8
on back of
pump tach.
2
Hex Wrench
Using 5/64 inch
or 2 mm hex
wrench turn
calibration fully
clockwise.
Tach Calibration