32
OPERA
TION
When finished, close the valve at the supply tank.
Drain the loading hose from the supply tank to the
fill connection.
WARNING
To prevent burns: Always wear insulated
gloves when handling spray bar sections or
hoses
Reduce the pump speed to 50GPM.
Close the valve at the storage tank.
Turn the “Return” valve handwheel fully counter
clockwise to the “Open” position.
Close the transfer valve.
Shut off the pump.
Slowly and carefully break the connection at the stor-
age tank and drain the line into a container.
Slowly and carefully break the connection the trans-
fer line and drain the hose into a container.
Replace the caps on the fill and transfer lines.
WARNING
Suckback of the storage tank line will put
material into the tank and could cause an
explosion if the tank has not been fully cleaned
of emulsion material
Figure 13. Valve Positions for Transfer
Transfer Operations
Set all of the valves and levers to their proper posi-
tions for transfer.
Close the Suction valve with the switch at the rear
panel.
Connect the loading hose from the supply tank to
the fill connection. Be sure that the connections are tight.
Connect the transfer hose from the transfer connec-
tion to the storage tank. Be sure that the connections
are tight.
When preparing to transfer, be sure that all of the
valves in the pump off line between the distributor and
the storage tank are open before opening the valve on
the storage tank containing liquid.
Open the Transfer valve.
Turn the “Return” valve handwheel fully clockwise
to the “Closed” position.
Turn the “Rotary Actuator” to the “Load/Suckback”
position.
Open the valve at the storage tank.
Slowly and carefully open the valve at the supply
source.
Start the pump and increase the pump speed to ap-
proximately 150 GPM using the “Circulation Rate”
switch in the cab or set the “Pump Control” switch at
the rear control panel to “Rear” and adjust the pump
speed using the “Pump Control” knob in the rear con-
trol panel.
Suck
Back
Off
Hand
Spray
Hand Spray Valve Positions
Suckback
Control Cylinder
Closed
Right
Suck Back
Valve
Closed
4 Way Valve
Load/Suckback
Suction Valve
Closed
Left
Suck Back
Valve
Closed
Handspray
Valve
Off
Transfer Valve
Open
Flush Valve
Closed
Hand Spray
Valve
Closed
Transfer Line
Suck Back
Valve
Closed
Return Valve
Closed
Some units may
have a butterfly
valve in place of
the return valve.
The butterfly valve
should be
Closed