W
ATLOW
®
EZ-ZONE
®
RMZ4
-
71
-
E
THER
CAT
®
A
DAPTER
Over-Temp Limit
Configures one over-temperature limit sensor per
control loop hosted by remote FM approved RMC or
RML
limit module
EtherCAT® Device Profile
ETG.5003.2060 Temperature Controller
Unique EtherCAT® Identifier
Two switches – 0x10, 0x01 for ID from 0 to 255
EtherCAT® LEDs
RUN and ERROR
EtherCAT® Connections
IN and OUT RJ-45
EtherCAT® PDO configurations
2 sets per loop:
o
One fixed default PDO set
o
One user programmable PDO set by loop
USB
Mini USB device providing a CDC serial port
Serial Connections
Standard bus RS-485 on slot “C” connector
Bluetooth
Serial Port Profile (SPP) streaming XML
Optical Temperature Sensor Inputs
4 max, set by model number
18
O
PTICAL
A
DDER
C
ARD
S
PECIFICATIONS
Feature
Specification
Optical Temperature Sensor Inputs
4 max, set by model number
ST bayonet style connectors IEC 61754-2
Environmental
-18 to 65°C operating
-40 to 85°C storage
0 to 90% RH, non-condensing
Supported Calibrated Probe Types
Type A – Watlow Standard
Type B
Type C – User Specific
Probe Range
-150 to +450
C Type A probe (Blue)
Accuracy (Unit to unit)
± 0.05
C
Precision (Sigma)
± 0.1
C
Resolution
0.0007 °C
Short Term Stability (Noise)
± 0.15
C
Long Term Stability (Drift)
± 0.5
C per year
Dynamic Sampling Rate
10 to 400 Hz
Weight
362 grams (12.8 oz) RMZ4 with 4 optical cards