Grand Hall Limited Warranty

Grand Hall will warrant to the ORIGINAL INSTALLED LOCATION of this gas water heater that it will be free of 
defects in material and workmanship for set period below from the date of purchase when installed and operated  
in accordance with the instructions in the manual and all local/state/federal codes.

Heat Exchanger Tank - 20 Years Residential / 10 Years Commercial No Leak Warranty
All Parts - 3 Years Limited Warranty / 5 Years Limited If Unit Registered Online 
Reasonable Labor-1 Year, Paid through Work Orders issued to registered contractors through our system

Grand Hall will require reasonable proof of your date of purchase.  Therefore, you should send in the owner 
registration card or register online at www.eternalwaterheater.com.  Save your receipt in case it is required as 
proof of purchase.
This Limited warranty is limited to repair or replacement of parts, at Grand Hall's option that proved to be 
defective under normal use utilizing potable water.
Grand Hall may require the return of defective parts  for examination before issuing replacement parts or repairs.  
If you are required to return defective parts, transportation charges must be prepaid.
No returns will be accepted without prior authorization from Grand Hall.
Upon  examination and to Grand  Hall's satisfaction, if the original part is proven defective  Grand Hall may 
approve your claim and elect to replace such parts without charge.  You are responsible for shipping charges of 
such replacement parts.
This Warranty does not cover any failures or operating difficulties due to accident, abuse, misuse, alteration, 
misapplication, vandalism, improper installation, maintenance or service, as set out in this Operator's Manual.
Deterioration  or  damage  due to severe  weather conditions such as  hail, hurricane,  earthquakes, tsunami, 
tornadoes, Acts  of  God  or  terrorism,  discoloration  due  to  exposure  to  chemicals  either  directly  or  in  the 
atmosphere, is not covered by this Limited Warranty.     
Only a licensed professional can install Eternal units for safety and code compliance. Venting and plumbing 
codes can vary by  location. Installation instructions and  all applicable  codes must be followed or  property 
damage, severe injury, or death can result. Failure to use a licensed plumber or contractor, follow venting, 
plumbing, and  building  codes; or follow  installation instructions may be  unlawful  and will void the  product 
warranty. Grand Hall is not responsible for any costs incurred for repairing any problems resulting from failure to 
follow installation instructions or applicable codes.
If service from authorized personnel is necessary to perform any work, you will be responsible for all labor 
charges outside of labor warranty period.
All replacement parts will carry out the remainder of warranty on the original parts.

To Obtain Warranty
Call 1-866-946-1096
7am - 7pm CST
Warranty Restrictions

This warranty applies only when the water heater is used in the United States and Canada.
This warranty gives you speci

 c legal rights, and you may also have other rights which vary from state to state.

This warranty does not cover damage resulting from use with non-potable water or water with high hardness 
level exceeding 450ppm. Water softener is recommended for areas with hardness over 200ppm.

Manufacturer:

Grand Hall Enterprise Co., Ltd.

9th Fl., No.298, Rueiguang Rd., Neihu,
Taipei,  Taiwan (114)


We encourage the use of the Internet for researching product attributes and for 

 nding quali

 ed installers that 

can properly size and service Eternal Hybrid Water Heaters. However, in the interest of safety and performance, 
our products must  be  installed  by  licensed  professionals since  the  connections  to  the  equipment  involve 
electrical, gas and water lines.
Grand Hall USA, Inc. does not support the sale of Eternal Hybrid Water Heaters to consumers over the Internet; 
including but not limited to auction sites. Such sales are strictly prohibited and no warranty is offered on Eternal 
Hybrid Water Heaters purchased over the Internet.
This  policy is  necessary  to  ensure that  installations  are safe  and comply  with applicable  laws,  rules,  and 
building codes at the federal, state, and local levels. Failure to comply with this policy could lead to violations of 
applicable laws that require licensing and permitting for installations of water heaters.
Websites or auctions claiming that any Eternal Hybrid Water Heater purchased online is covered by Grand Hall

warranty are incorrect and falsely advertising.

Internet Sales Policy

Summary of Contents for GU145 Series

Page 1: ...maintained Failure to follow these instructions exactly could result in a re or explosion serious bodily injury and or property damage Do not store or use gasoline or other ammable vapors and liquids...

Page 2: ...entric Vent Kit Outdoor Vent Kit Installation P25 Vent Pipe Installation Terminator Position P26 Gas Supply Piping P27 LP Conversion P28 Water Supply Connection P29 Condensate Piping P30 Temperature a...

Page 3: ...3 Included Accessories Optional Accessories 0 75mm 2C Wire Hole Plug 1pcs Self Tapping Screw 5 32 x 5 8 2pcs Cap 2pcs Philips Head Screw M8x15 4pcs...

Page 4: ...jection Metal Fiber Infrared Gas Valve System Dual Stage Negative Pressure Full Modulation Air Ratio Internal Piping Material Standard Copper S Option 316L SS M Option 316L SS MCU Reserve Tank Under 2...

Page 5: ...5 Dimensions GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M...

Page 6: ...6 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M...

Page 7: ...7 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S...

Page 8: ...ollar Packing 13 Rubber Foot 14 Drain Valve Assembly 15 Main Power Cord 16 Handle 17 Condensing Nipple 18 Plug 19 Mesh Screen 20 Outdoor Venting Cap Optional 21 Trap Cleaner Assembly 22 Radial Blower...

Page 9: ...9 Parts Diagram for Model GU195 S 508 11 12 21 22 1195 S Parts Diagram for Model GU195 M 508 11 12 21 22 1195 M...

Page 10: ...lve Cash Acme 11 Vent Collar 12 Vent Collar Packing 13 Rubber Foot 14 Drain Valve Assembly 15 Main Power Cord 16 Handle 17 Condensing Nipple 18 Plug 19 Mesh Screen 20 Outdoor Venting Cap Optional 21 T...

Page 11: ...matically lights the burner Do not try to light the burner by hand Smell all around the water heater area for evidence of leaking gas Be sure to smell next to the oor because LP gas is heavier than ai...

Page 12: ...through an outside wall or through the roof using 3 vent piping the total vent run cannot exceed 95 feet with one 90 elbow If more elbows are required the venting distance must be reduced 5 feet for...

Page 13: ...n When this occurs the trap must be cleaned CLEAN OUT OF TRAP The condensate trap must be lled with water prior to using the water heater Fill 3 0 oz water through exhaust collar per gure 1 Eternal wa...

Page 14: ...ng should give a minimum free area of one square inch per 15 000 Btu hour of the total input ratings of all appliances in the enclosed area When combustion air is supplied from inside the building eac...

Page 15: ...of the appliance Locate the water heater in an open unroofed area and maintain the above minimum clearances from combustible materials Exhaust Ventilation Do not have the ue terminal pointing toward...

Page 16: ...nstallation of water heaters in manufactured homes mobile homes and Recreational Park Trailers In the absence of such a standard the water heater should be installed in accordance with the latest edit...

Page 17: ...f the framing is not standard or installing on an uneven surface fasten 3 4 plywood to the stud wall and then attach the wall bracket Hang the unit on the mounted wall bracket and secure bottom of the...

Page 18: ...must be elevated at least 6 off the floor This mounting clearance provides access for clearing any possible debris or accumulated water seepage that can occur below the unit Install the unit on Eterna...

Page 19: ...n vent with the vent pipe of any other water heater or appliance NOTICE VENTING GUIDELINES This water heater must be properly vented for removal of exhaust gases to the outside atmosphere Correct inst...

Page 20: ...to the intake collar for future serviceability Reduce the maximum allowable length for each elbow used as follows 45 degree elbow Deduct 2 feet 90 degree elbow Deduct 5 feet How To Con gure Unit For P...

Page 21: ...xisting vent piping or chimney The total vertical and horizontal runs cannot exceed the maximum length with a maximum number of 90 degree elbows as speci ed in the table of page 20 Eternal can be vent...

Page 22: ...pipe Vent pipe must exit exterior wall horizontally only Place the 1 2 metal mesh screen inside the terminal tting and connect it as shown to the vent pipe on the exterior of the building Seal any op...

Page 23: ...lly vented but next unit vent ternination must be at least 12 inches away from the first unit It is important that vent terminatiion to avoid recirculation of flue gases Concentric Multivent Terminati...

Page 24: ...The connection for the flue gas and air intake system can be positioned on the right as well as on the left side of multi control units Direct Vent Sealed Vent Multi Units With Common Vent POWER VENT...

Page 25: ...ccur and may cause intermittent operation WARNING Outdoor Vent Kit Philips Head Screw M4xL8x6pcs Intake louvers Exhaust Installations must be made with a vent pipe system certi ed to ULC S636 The rst...

Page 26: ...Clearance to each side of center line extended above meter regulator assembly 3 feet within a height 15 feet above the meter regulator assembly I Clearance to service regulator vent outlet 3 feet J C...

Page 27: ...inish and it would not be able to reach maximum performance Size gas piping system correctly following ANSI Z223 1 NFPA 54 or by local code Based on 0 60 specific gravity for natural gas at 0 5 W C pr...

Page 28: ...13 w c maximum pressure Contact the local propane gas supplier for recommended sizing of piping tanks and 100 lockup gas regulator NOTICE 5 Reassemble front panel and apply LP label Prior to start up...

Page 29: ...ING Close water supply shut off valve to the unit rst Connect garden hose to the draining valve located on the lower leftsider of the unit Open the valve by using a at head screw driver to drain water...

Page 30: ...nearest drain is above the water heater will require the use of a condensate pump Size the pump to allow for a maximum condensate discharge of 2 GPH from the water heater Horizontal runs must be slop...

Page 31: ...te Internal Pump Control Function Step 1 Push 1 switch of group 2 like below gure Step 1 Unplug power cord of unit Step 2 Make the hole on right side of panel and get rid of burr Step 3 Insert the pum...

Page 32: ...A battery back up may be used to supply hot water during periods of power outages We recommend a computer grade UPS uninterruptable power supply with at least 600VA rating for extened coverage Ground...

Page 33: ...ng 5 screws 3 Open one of the pre cut holes on either side panels of the unit and insert the hole plug 1 Open the main controller PCB cover by removing 1 screw 2 Run wire from the PCB to where the rem...

Page 34: ...of the remote display by loosening 2 screws Secure the Remote controller to the Wall Anchors using the included Mounting Screw 2 pcs and replace the cover to hide the mounting hardware Remote Display...

Page 35: ...NBUS Protocol ensures good communication between units Alternate Host Firing distributes wear and tear across all units every 24 hours Redundancy program allows remaining units to work when a units br...

Page 36: ...power outlet 1 Make sure dip switch 4 to ON position Group 1 No 4 2 Make sure dip switch 6 7 8 OFF position Group 2 No 6 7 8 3 When this switch is on CAN Control Area Network engine is enable and all...

Page 37: ...Installation Operating as a single unit Eternal consumes less than 1A current and the power supplied to unit can be on as low as 2A capacity However when multiple Eternals are used together power sup...

Page 38: ...tion System with an Eternal Water Heater Single Eternal with Storage Back up These diagrams are for reference as basic guides Each installation should be engineered properly and compliant to Local and...

Page 39: ...culation with 2 Units manifold Single Eternal with pre heater i e Solar These diagrams are for reference as basic guides Each installation should be engineered properly and compliant to Local and Stat...

Page 40: ...m with Multiple Units Connection Multiple Units Connection with Storage Back Up These diagrams are for reference as basic guides Each installation should be engineered properly and compliant to Local...

Page 41: ...stat pump and set at 20 F below Eternal temperature setting If unit is not controlling pump by internal relay Size the pump to provide a minimum of 5 0GPM through the system at 10ft of head plus pipin...

Page 42: ...s piped so that its outlet will be farthest from the hot water supply line NOTICE Reverse return system In above drawing there is no path of least resistance water flow will be adequate in each unit R...

Page 43: ...inlet water tubing size 3 4 inches Has a combined T P relief valve been installed Does this valve have a discharge line installed and is it piped to a free owing drain Have all the plumbing connection...

Page 44: ...pening the nearest hot water faucet Allow water to run until a constant ow is obtained This will let air out of the water heater and piping Open a hot water tap to check that water will ow to that tap...

Page 45: ...re setting is only adjustable when the burner is not in use The maximum water temperature setting can be limited by DIP switches This manual setting overrides adjustable temperature settings on the fr...

Page 46: ...st the water temperature Press the either the Hotter up or Cooler down temperature setting button with the unit ON temperature setting is only adjustable when the burner is not in use To lock the cont...

Page 47: ...pection A visual inspection should be made on the venting system at least once a year Clean Up The ue outlet and the air intake hole on the top of the water heater should be checked Clean as needed to...

Page 48: ...48 DIAGNOSTICS Before calling for service review the following diagnostic steps rst for saving time and money...

Page 49: ...wn operation continuously If an error occurs a message will flash on the digital monitor of the front panel This assists with diagnosing the error and may enable you to overcome a problem without a se...

Page 50: ...p OFF then ON again If this does not clear the Error Message try pushing the ON OFF button OFF then ON again If the Error Message still remains contact our service center or your nearest service agent...

Page 51: ...to the water heater Turn the water heater on and open multiple taps to force unit into high re check gas supply pressure at the test port with a manometer with unit in high re Turn the water heater ON...

Page 52: ...52 Wiring and Connection Diagram Wiring Diagram MODEL GU145 S 508 11 12 21 22 1145 S GU195 S 508 11 12 21 22 1195 S...

Page 53: ...53 Wiring and Connection Diagram Wiring Diagram MODEL GU195 M 508 11 12 21 22 1195 M...

Page 54: ...licable codes must be followed or property damage severe injury or death can result Failure to use a licensed plumber or contractor follow venting plumbing and building codes or follow installation in...