36
MCU Installation
Connect Female Termination Wire to MCU Wire at the
rst unit
5.
Connect Male Termination Wire to MCU Wire at the last unit
7.
Plug the power cord of the unit and turn the power ON.
8.
With all taps closed and unit off, unplug the power cord of the unit from the power outlet.
1.
Make sure dip switch #4 to ON position (Group 1, No.4)
2.
Make sure dip switch #6, 7, 8 OFF position (Group 2, No. 6, 7, 8)
3.
When this switch is on, CAN(Control Area Network) engine is enable and all units will communicate with each other.
If you need more detail information ID setting, refer to page 37
“
Unique Unit Identification Number
”
.
Connect MCU Wire to main controller
4.
MCU Installation
Connect MCU Wire to next MCU Wire
6.
Female Termination Wire
Male Termination Wire