25
Concentric Vent Kit
Do not operate the appliance with the rain cap removed or recirculation of combustion byproducts may occur.
Water may also collect inside the larger combustion air pipe and
ow to the burner enclosure. Failure to follow
this warning could result in product damage or improper operation, personal injury, or death.
Do not allow insulation or other materials to accumulate inside the pipe assembly when installing through the
hole. Ensure termination height is above the roof surface or anticipated snow level (12 inches in USA or 18
inches in Canada).
Do not field-supplied couplings to extend pipes. Airflow restriction will occur and may cause intermittent
operation.
□
□
□
WARNING
Outdoor Vent Kit
Philips Head Screw
M4xL8x6pcs
Intake louvers
Exhaust
!
!
Installations must be made with a vent pipe system certi
ed to ULC-S636.
The
rst three (3) feet of plastic vent pipe from the appliance
ue oulet must be readily accessible for visual
inspection.
The components of the certi
ed vent system must not be interchanged with other vent systems or unlisted
pipe/
ttings. The inner vent tube must be replaced with
eld supplied certi
ed vent material to comply with this
requirement.
□
□
□
Requirements for Installation in Canada
NOTICE
!
!
"Y" Concentric Fitting
4" DIA
SDR-26 Pipe
2
½
" DIA
SDR-26 Pipe
Rain Cap
3" Connectors
3" DIA PVC Pipe
Installation Instructions:
1. Remove included 6 screws on the unit.
2. Install the 3" DIA PVC Pipe.
3. Install the Outdoor Vent Kit on the unit with included
6 screws.
Summary of Contents for GU145 Series
Page 5: ...5 Dimensions GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M...
Page 6: ...6 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S GU195 S M 508 11 12 21 22 1195 S M...
Page 7: ...7 Parts Diagram for Model GU145 S 508 11 12 21 22 1145 S...
Page 53: ...53 Wiring and Connection Diagram Wiring Diagram MODEL GU195 M 508 11 12 21 22 1195 M...