Vertical Termination
Below diagrams are examples of vertical terminations.
Through roof (Direct Vent)
Through roof (Concentric Vent)
Through roof (Power Vent)
□
□
□
Minimum twelve (12) inches above anticipated
snow level.
It cannot be connected to existing vent piping or
chimney.
The total vertical and horizontal runs cannot exceed
the maximum length with a maximum number of 90
degree elbows as speci
ed in the table of page 20.
Eternal can be vented straight up and horizontal
section is not required for vertical terminations.
□
□
□
□
WARNING
!
!
An open tee is optional and can be
used as termination to alleviate back
pressure in the venting system in areas
experiencing abnormally high winds