19
Vertical Termination
Below diagrams are examples of vertical terminations.
Through roof (Direct Vent)
Through roof (Concentric Vent)
Through roof (Power Vent)
□
□
□
Minimum twelve (12) inches above anticipated
snow level.
It cannot be connected to existing vent piping or
chimney.
The total vertical and horizontal runs cannot exceed
the maximum length with a maximum number of 90
degree elbows as specified in the table on page 18.
Eternal can be vented straight up and a horizontal
section is not required for vertical terminations.
□
□
□
□
WARNING
!
!
An open tee is optional and can be
used as a termination to alleviate back
pressure in the venting system in areas
experiencing abnormally high winds.
The Grand Hall approved concentric kit is a unique
pipe-in-pipe venting system designed for termination.
Do not try to replicate or make your own. For more
information, please refer to
Concentric Vent Kit
section in the Operation manual.
WARNING
!
!