7
Selador Series User Manual
Installation
Power and Data Cabling Requirements
Power
The Selador series fixture operates on AC power, 100 to 240VAC/50-60Hz. You may use
a circuit powered through an SCR dimmer, as long as the dimmer is set to unregulated
non-dim (switched) operation.
Power is supplied through a standard five-foot power-input cable with Neutrik PowerCon
locking pigtail with either an Edison, Twistlock™, or Stage-pin male connector.
Data
The Selador series fixtures operate on a DMX control signal. The unit is supplied with a
5-pin XLR DMX input connector and a 5-pin DMX Thru connector. DMX cables should be
acceptable for DMX data transmission (not microphone cable) and should follow the
standard pinout. The optional secondary data pair is not used by the Selador series fixtures.
The maximum DMX data run from any DMX source to the last fixture in a chain is 1000 feet
(300m). Termination is required in the data thru port of the last fixture in each data chain.
for additional information on DMX addressing of Selador Series
fixtures.
DMX512 pinout for five-pin XLR female
1
Common (Shield)
2
Data –
3
Data +
4
not connected
5
not connected
Push
1
2
3
4
5