ETC Installation Guide
ColorSource Spot V1.0
Mounting
The ColorSource Spot V ships with a standard yoke for mounting with a
clamp. You can adjust the position of the yoke when necessary for low-
clearance mounting.
Standard yoke position
Low-clearance yoke position
You can attach a ColorSource Relay to the yoke. See
for
more information about ColorSource Relay.
Safety cable
attachment loops
Safety Cable
A safety cable (or other approved
safety device) must be attached to the
fixture. Attachment loops are on the
rear of the fixture. Leave as little slack
as possible in the safety cable to
avoid catching the yoke of the fixture.
Connectors
•
Power: Two powerCON
®
TRUE1
®
connectors for power in and thru
•
Data (DMX512/RDM): Two five-pin XLR connectors for data in and
thru
Note:
The ColorSource Spot V is not self terminating. You must
terminate the last fixture in line with a 120 Ohm resistor. To
purchase a terminator, please contact ETC customer service and
request part number SGE1507 (XLR terminator).
ColorSource Spot V
Page 5 of 20