ES5392.1 High Current Switch Board (6-CH) - User’s Guide
24
Design, Installation and Fuses
ETAS
2.5.2
Configuration of Digital Inputs/Outputs of X1 PwrCtrl
There are five connection strips on the ES5392.1 for jumpers that are used for
configuring the digital inputs/outputs of X1 (PwrCtrl) to an external power sup-
ply. Fig. 2-5 shows the position of the jumpers.
Fig. 2-5
Position of jumper connection strips
Mapping of connection strips for the jumpers to the digital inputs
of X1 PwrCtrl
Tab. 2-2
Mapping of jumper connection strip to the digital inputs
Position of Jumpers on the Connection Strips JP800, JP801 and JP802 for the
Digital Inputs of X1 PwrCtrl)
Tab. 2-3
Position of jumpers for the digital inputs of X1 PwrCtrl
The block diagram of the digital inputs is located in Fig. 3-2 on page 33.
Jumper
Dig. input
JP800
DIG_IN_0
JP801
DIG_IN_1
JP802
DIG_IN_2
Position
Function
Pin 2-3
Pull-up circuit active (default configuration)
Pin 1-2
Pull-down circuit active
Unpopulated
Push-pull mode
Note
Ensure that Pin 1 and Pin 3 of neighboring connection strips are not connected
by a jumper.
JP80
2
JP803 JP804
JP80
1
JP80
0
1
2
3
1
2
1
2
3
1
2
3
1
2