![eta BE-P3 Installation Manual Download Page 7](http://html1.mh-extra.com/html/eta/be-p3/be-p3_installation-manual_2430221007.webp)
Installation
Exchange for PelletsUnit/ PelletsCompact
7
3
Installation
Assembly and installation only by qualified
specialist personnel
The assembly and installation may be performed
by specialist personnel with the corresponding
qualifications only.
DANGER!
Electric shock
There are live parts on the circuit boards. If
touched, they can cause injury and
property damage.
Before beginning any work, isolate the system
completely from all power sources, ensure that it
cannot be switched back on, and verify that it is
safely isolated from supply.
3.1
Exchange for PelletsUnit/
PelletsCompact
Technical illustrations
The following describes how to exchange the control
panel of the PelletsUnit boiler and is also applicable to
the PelletsCompact boiler.
Dismantle defective control panel
Detach the front panel of the boiler.
Fig. 3-1: Front panel
First, remove the panelling on the top. To do so,
completely unscrew the cheese-head screw next to
the flue connection to the chimney. Next, press the lock
and lift off the panel.
Fig. 3-2: Panel
Unscrew the screws on the control panel panelling and
carefully lift the panel.
Fig. 3-3: Panel
Disconnect all lines on the control panel. Unscrew the
screws that attach the frame to the panel.
Fig. 3-4: Control panel
Disconnect the defective control panel from the frame.
Summary of Contents for BE-P3
Page 19: ......
Page 20: ...www eta co at www eta co at downloads DOWNLOAD...