7

3

Installation

Assembly and installation only by qualified
specialist personnel

The assembly and installation may be performed
by specialist personnel with the corresponding

qualifications only. 

DANGER!

Electric shock

There are live parts on the circuit boards. If
touched, they can cause injury and
property damage.

Before beginning any work, isolate the system
completely from all power sources, ensure that it
cannot be switched back on, and verify that it is
safely isolated from supply.

3.1

Exchange for PelletsUnit/ 

PelletsCompact

Technical illustrations

The following describes how to exchange the control
panel of the PelletsUnit boiler and is also applicable to
the PelletsCompact boiler.

Dismantle defective control panel

Detach the front panel of the boiler.

Fig. 3-1: Front panel

First, remove the panelling on the top. To do so,
completely unscrew the cheese-head screw next to
the flue connection to the chimney. Next, press the lock
and lift off the panel.

Fig. 3-2: Panel

Unscrew the screws on the control panel panelling and
carefully lift the panel.

Fig. 3-3: Panel

Disconnect all lines on the control panel. Unscrew the
screws that attach the frame to the panel.

Fig. 3-4: Control panel

Disconnect the defective control panel from the frame.

Summary of Contents for BE-P3

Page 1: ...2017 08 23 EN 0000000360 V 003 X 35 6 X 40 1 939016 002 Replacing the control panel on the BE P3 Installation...

Page 2: ...ETA Heiztechnik Gewerbepark 1 A 4716 Hofkirchen an der Trattnach Tel 43 0 7734 22 88 0 Fax 43 0 7734 22 88 22 info eta co at www eta co at...

Page 3: ...12 3 4 Exchanging a BE P3 14 4 Concluding activities 15 4 1 Setting node numbers 15 4 1 1 Up to software version X 35 X 15 4 1 2 Software version X 36 0 and later 15 4 2 ETAtouch software update 16 4...

Page 4: ...ors or changes of any kind made in the interim are not cause for claims Individual configurations depicted or described here are only available optionally In the event of contradictions between indivi...

Page 5: ...and 3 XX X for BE P3 As a precaution you can also download all software versions for the user interface up to X 35 X 1 35 X 2 35 X and 3 35 X and the versions from X 36 0 e g 2 39 0 and 3 39 0 You ca...

Page 6: ...BE P2 the node number is only displayed in the ETAtouch control system Depending on the software version installed up to X 35 X or from X 36 0 the set node numbers are displayed differently Up to soft...

Page 7: ...xchange for PelletsUnit PelletsCompact Technical illustrations The following describes how to exchange the control panel of the PelletsUnit boiler and is also applicable to the PelletsCompact boiler D...

Page 8: ...on top Fig 3 5 Attachment Plug the supplied USB cable angled plug and socket to the side of the control panel and attach the socket to the frame Fig 3 6 USB cable Connect the USB adapter cable part o...

Page 9: ...ctive control panel Remove the cover plate on the inside of the insulation door Fig 3 8 Cover plate Remove the four screws on the side and carefully take the cover with the control panel out of the to...

Page 10: ...mplate Fig 3 13 Side view with enlarged cut out Fig 3 14 Cutting template After cutting out seal the cut edges with a coating to prevent rust from building up Mount new control panel The two side tabs...

Page 11: ...the existing boiler USB cable If a network cable was previously connected also connect it to the control panel Fig 3 19 USB adapter cable Attach the USB cable from the boiler to the door frame with a...

Page 12: ...e the defective control panel Fig 3 22 Control panel Enlarge cut out for the new control panel if desired The new control panel protrudes slightly due to the existing cut out in the cover See the foll...

Page 13: ...the cover has not been enlarged Fig 3 26 Break off tabs Insert the new control panel and carefully attach it with the retaining plate and two screws Note the correct alignment of the control panel The...

Page 14: ...the frame to the panels 3 4 Exchanging a BE P3 Replacing the BE P3 control panel The BE P3 control panel is replaced by a new BE P3 in the same way as described in the previous chapters However only...

Page 15: ...System configuration A window with the system settings appears 6 Press the Change button next to CAN node switch A window appears where you can enter the desired node number The values 0 to 7 are perm...

Page 16: ...he ETAtouch control panel of the boiler itself and on all further ETAtouch control panels 1 Plug the USB memory stick with the files for the software update into the ETAtouch control panel 2 Press the...

Page 17: ...ars to remove the USB memory stick After removing the USB memory stick the ETAtouch control panel will restart automatically The software update was successfully installed and completed when the symbo...

Page 18: ...18 www eta co at Cutting template 5 Cutting template Cutting template for BE P3 The cutting template is depicted at 1 1 scale...

Page 19: ......

Page 20: ...www eta co at www eta co at downloads DOWNLOAD...

Reviews: