16
www.eta.co.at
Adjusting the log boiler
Installation
3. Remount the nuts and washers on both axles.
Remount the self-tapping screw in the lower air
box.
Fig. 4-12: Nuts, discs, self-tapping screws
4. Mount both twist guards on the opposite side in the
brackets.
Fig. 4-13: Twist guards
Remove insulation
The required cut-out for the pellet burner cleaner is
precut into the boiler insulation. Trim it with a knife and
remove the insulation.
Fig. 4-14: Cutting out the insulation
Fig. 4-15: Remove insulation
Milling opening for flame pipe
Remove the flange plate and the 3 threaded rods.
Fig. 4-16: Flange plate