![eta 11120L Installation Manual Download Page 11](http://html1.mh-extra.com/html/eta/11120l/11120l_installation-manual_2430201011.webp)
Technical data
Energy Labelling
11
Tab. 2-1: Product data according to EU Regulation 2015/
1187 and 2015/1189
Seasonal space heating emissions - OGC
mg/m³
(10% O
2
)
<30
<30
<30
<30
<30
Seasonal space heating emissions - CO
mg/m³
(10% O
2
)
<700
<700
<700
<700
<700
Seasonal space heating emissions - NOx
mg/m³
(10% O
2
)
<200
<200
<200
<200
<200
Other suitable fuel
Pellets
Maximum load
kW
20
26
40
40
49.9
Partial load
kW
6
7.5
12
12
14.3
Efficiency (in terms of gross calorific value) at maxi-
mum load
%
83.1
84.2
82.8
82.8
81.7
Efficiency (in terms of gross calorific value) at partial
load
%
79.2
81.4
81.3
81.3
81.2
Electrical power consumption at maximum load
kW
0.061
0.102
0.116
0.116
0.116
Electrical power consumption at partial load
kW
0.046
0.057
0.066
0.066
0.067
Electrical power consumption in ready mode
kW
0.012
0.013
0.012
0.012
0.012
Seasonal space heating energy efficiency
%
75
77
77
77
77
Seasonal space heating emissions - dust
mg/m³
(10% O
2
)
<40
<40
<40
<40
<40
Seasonal space heating emissions - OGC
mg/m³
(10% O
2
)
<20
<20
<20
<20
<20
Seasonal space heating emissions - CO
mg/m³
(10% O
2
)
<500
<500
<500
<500
<500
Seasonal space heating emissions - NOx
mg/m³
(10% O
2
)
<200
<200
<200
<200
<200
Wood chip boiler SH with pellet burner TWIN
Unit
Model identification
SH 20P
+
TWIN20
SH 30P
+
TWIN26
SH 32P
+
TWIN40
SH 40P
+
TWIN40
SH 50P
+
TWIN50