T1
T2
T3
T4
T5
10Hz
15Hz
25Hz
35Hz
50Hz
10Hz
15Hz
25Hz
35Hz
50Hz
40Hz
150Hz
200Hz
250Hz
350Hz
NOTE:
If the amplifier's top-panel is white illuminated, the amplifier is in power mode. If the display is red illuminated,
the protection mode of the amplifier is activated caused by a malfunction (See page 19)
CAUSES:
Overheating, short circuit on the speakers, overload (caused by low-impedance or low-power) or damage .
T1
SUBSONIC FILTER
Controls the cut-off frequency downwards because
too low frequencies can cause damages
to your Subwoofer. It is variable between 10Hz - 50Hz.
T2
LOW PASS
Controls the cut-off frequency of the lowpass, that means
the frequency response is limited upwards.The cut-off frequency
is continously variable from 40 Hz up to 350 Hz.
T3
BASS BOOST
This switch allows you to adjust the bass boost from
0 up to 18 dB. Please use the Bass Boost carefully.
T4
INPUT GAIN
Adjusts the input sensitivity of the input signal from 0,15 up to 9 Volts.
T5
ACOUSTIC PHASE SHIFT LEFT
Controls the Phase between 0 - 180 degrees, this feature allows
to move the virtually soundstage position of the Subwoofer.
FUNCTIONS & CONTROLS TOP PANEL
Monoblock Amplifier VE1000.1 / VE1800.1
15
T6
DISPLAY
If the display is lighten up in white, the amp is in ready for use.
If the display is lighten up red, a malfunction is to be on hand
and the amplfier's PROTECTION MODE is active.
T6