2.3.3 IGNEO Compact
1. Disconnect the controller from the power and remove the batteries from the transmitter
2. Connect the set to the controller according to the diagram above.
3. Activate the controller and replace batteries in the trnasmitter.
4. In the controller, enter the heating and indicate "CTP2" as a sensor of room temperature.
(step-by-step instruction is presented in point 2.3.4 on page 11)
5. End of installation. You can operate the controller now.
SIGNAL LEDs:
:
When installed correctly, the red LED of transmitter should flash briefly every
1,5 minute (sends information). The green LED of receiver should light up after it has received the
information from the transmitter. If the set does not operate correctly in spite of correct signalling, you
should remove and replace the batteries in the transmitter.
page 10