GEFRAN SpA
Via Sebina, 74 - 25050 PROVAGLIO D’ISEO (BS) ITALY
This Quick Start Guide provides basic information on
setting up the Gefran 1200 controller for the application
referenced above. Additional software and hardware
configuration information can be found in the User’s Manual
included with this controller or online at www.gefran.com
If needed, automatic tuning (Self-Tune) can be enabled
with the following steps
• Press and hold
F
until
CFG
appears
• Press
F
once,
S.Tu
appears —
ENTER
2
• Press
F
once
• Cycle power to the controller
• LED 3 (
L3
) will flash during the tuning process
With the machine at ambient temperature and
the control setpoint (SV) set...
Self-Tune will automatically save new PID
values once complete
Note
Change all menu parameters by
using the front panel buttons
GETTING STARTED
• Unpack Contents
• Verify model numberand application
• Power Controller
• Program for yourapplication
Program Your Gefran Controller
2
* Parameter may be left at default value for input types 0...37
Input Sensor
Sensor Type
Sensor Type
0 TC J °C
30 PT100 °C
1 TC J °F
31 PT100 °F
2 TC K °C
32 JPT100 °C
3 TC K °F
33 JPT100 °F
4 TC R °C
34 PTC °C
5 TC R °F
35 PTC °F
6 TC S °C
36 NTC °C
7 TC S °F
37 NTC °F
8 TC T °C
44 4...20 mA
9 TC T °F
46 0...10 V
Connect Your Controller
3
What’s Included
• 48x96 DIN 1200-RD00-00-0-x
Gefran Controller x2
• Mounting Bracket
• Panel Sealing Gasket
• Screw Terminal Cover
• Multi-Language Manual
1
• Press and hold
F
until
PAS
appears —
ENTER
99
• Press
F
once,
Pro
appears —
ENTER
128
• Press
F
once,
PAS
appears —
ENTER
99
• Press and hold
F
until
Hrd
appears
• Press
F
repeatedly until
but
appears —
ENTER
1
• Press and hold
F
until
1 nP
appears
• Press
F
twice,
tYP
appears —
ENTER
the Input Sensor number
from the list
• Press
F
repeatedly until
Lo.S
* appears —
ENTER
the minimum Input Scale limit
• Press
F
once,
H i.S
* appears —
ENTER
the maximum Input Scale limit
• Press
F
repeatedly until
Lo.L
* appears —
ENTER
the minimum Alarm Scale limit
• Press
F
once,
H i.L
* appears —
ENTER
the maximum Alarm Scale limit
• Press and hold
F
until you return to the main process display. This is the display after
PAS
and will be indicated by the Process Variable if an input sensor is connected, or
Lo
,
H i
,
Sbr
,
Err
if no input is connected.
• Use the and buttons to adjust the control setpoint (SV) from the main display.
• Press
F
once from the main display,
AL.1
appears to adjust the Alarm 1 setpoint.
• Press the
button to switch between automatic and manual control modes from the
main display. LED 1(
L1
) will light while in manual mode.
POWER
Additional wiring
configurations
are available
in the User’s
Manual and
General Setup
Guide
Quick Start Guide
1200-RD00-00-0-x
Programmable PID Controller
2
-
1
+
7
8
11
10
6
-
5
+
ALARM
Heat & Alarm
HEATER
POWER CONTROL
THERMOCOUPLE