2.3.4 Settings in the controller of boiler
After the receiver has been connected correctly, you should select" CTP2 " in the controller of
central heating boiler as a sensor of temperature. From the main display enter the functions one by
one : Heating->Circuit n (number)->Service->Enter password > Room sensor>Select CTP2.
3 Utilization
3.1 Signal LEDs
TRANSMITTER
•
LED flashes – sending data, takes every 1,5 minute in the normal mode, in continuous
transmission mode– every second.
•
LED flashes all the time – presumably the transmitter has been suspended, so the
battery should be removed and replaced.
RECEIVER
•
LED flashes for 20 seconds every 1,5 minute – the receiver gets the adjusted temperature
from the transmitter in the normal mode every 1,5 minute.
•
LED flashes every second – the receiver gets data all the time, presumably the
transmitter is in continuous transmission mode.
•
LED flashes twice (for a short and long time) every 5 seconds – the receiver has not
received any data for 30 minutes.
3.2 Adjustment of temperature
You can adjust the temperature using the knob. Neutral setting is a default location, which does
not have any impact on the temperature set up. The temperature is sent to the receiver every 1,5
minute.