E-S 500 / 502 Classic Series Instruction Manual
3.8
Temporary Safety Jumpers & Dip Switch Settings
If you are not using a safety device like a
photo eye or safety loop the Photocell
terminal must remain jumped to the GND
terminal.
Dip Switches
—To change any dip switches, you must turn the power
off before changing the setting.
ON:
Auto-close on (the gate will re-close from
the open position after a time set in the pro-
gramming section)
OFF:
Auto-Close off
ON:
Dual gate opener (2 motors)
OFF:
Single gate opener (1 motor)
ON:
Electric Lock being used
OFF:
Electric Lock not used
IMPORTANT:
We recommend before turning the gate opener
on for the first time to have dip switch 1 OFF. If the dip switch is
set to on, the gate will auto-reclose after turning it on without
any intentional activation on your part.
1.
2.
3.
Photo jumped to GND