Display:
RESET
will set the displayed quantity back
to 0,00
TOTAL
will display the overall total.
FLOW RATE
will display the instantaneous flow rate.
The
SELECT
key is needed for the calibration process.
The LCD display will automatically switch off when it has not been used for around 30 seconds.
The display will be activated automatically when flow starts or by pressing the
TOTAL
key. Please
note that a displayed quantity will remain in memory even if the display has switched off automatically.
Technical Data:
Flow rate measurement range:
0,5 – 40 l/min.
Maximum permissible pressure:
80 bar
Measurement
accuracy:
+/- 0.5%
Permissible
temperature range:
-10
°
C to max. +60
°
C
Viscosity of the pumped fluid:
5 – 5000 mPa.s
Size (measurement housing
without accessories)
Ø 92 * 115 mm high
Weight (measurement housing
without accessories)
0.75 kg
Pumped media:
Diesel, heating oil, hydraulic oils (mineral and glycol based),
engine and transmission oils (other media on request)
Partial total display (resettable):
from 0.00 to 9999.99
Overall total display (not resettable):
from 0 to 999999 (6 characters)
Power supply:
2 x 1.5V Mignon LR 6
Battery life:
Around 1 million litres depending on use
Materials:
Housing / cover:
Aluminium / PA fibre reinforced
Display panel:
Plastic
Oval gears:
PA fibre reinforced
Shaft, cover screws
Steel
Seal:
NBR 75
Battery replacement:
Only use 1.5V Mignon LR 6 batteries. Watch the polarity when inserting the battery.
Ensure that when changing the battery the counter is „OFF“ or is set to 0.00 with „RESET“.
To change the battery, release the side housing screws and remove the meter.
If the counting function does not work after changing the battery, the meter will have to be recalibrated.
Do not put flat batteries into household waste. Dispose of used batteries in the proper manner.
Safety Instructions:
Ø
Comply with the permissible pressures for the meter.
Ø
Repair work must only be carried out by trained specialist personnel.
Ø
Comply with the details and notes given Operating Instructions.
Ø
Do not use the meter in EX-protected areas.