background image

 
 
We recommend replacing the AirCare® filter at least once a year and more often if 
necessary.  When the white filter media is coated with a layer of dust and dirt, it is time 
to replace the AirCare® filter.  The certified water output of your humidifier will be 
reduced when using the AirCare® filter.  AirCare® filters are optional and are not 
required for normal operation of the humidifier. AirCare® is registered trademark of 
Essick Air Products. 

CARE AND MAINTENANCE  

CAUTION: 

Disconnect power before filling, cleaning or servicing unit. Keep grille dry at 

all times.

 

Cleaning your humidifier regularly helps eliminate odors and bacterial and fungal 
growth.  Ordinary household bleach is a good disinfectant and can be used to wipe out 
the humidifier base and bottle/reservoir after cleaning.  We recommend cleaning your 
humidifier at least once every two weeks to maintain optimum environmental conditions 
for your home. 

We also recommend using Essick Air Bacteriostat Treatment each time you refill your 
humidifier to eliminate bacterial growth.  Add bacteriostat according to the instructions 
on the bottle.  Please call 1-800-547-3888 to order Bacteriostat Treatment reference 
part number 1970.   
1.  Turn off unit completely counterclockwise and unplug from outlet. 
2.  Lift out the water bottle and the power pack.  
3.  Carry bottle and base to cleaning basin. Lift wick from the base allowing the water 

to drain. Rinse wick under fresh water only.  Do not use soap, detergent, or any 
other cleaners on the wick.  Leave in sink to drain. 

REMOVING SCALE  

4.  Empty the water from the reservoir and water bottles.  Fill reservoir and each water 

bottle ½ full with water and add 8 oz. (1 cup) of white vinegar to each.  Let stand 20 
minutes.  Then empty solution. 

5.  Dampen a soft cloth with white vinegar and wipe out reservoir to remove scale. 

Rinse the water bottles and reservoir thoroughly with fresh water to remove scale 
and cleaning solution before disinfecting.  

DISINFECTING UNIT  

6.  Fill each water bottle and reservoir ½ full with water and add 1 teaspoon of bleach 

to each.  Wipe cabinet and bottle surfaces with this solution. Let solution stay for 20 
minutes, then rinse with water until bleach smell is gone. Dry with clean cloth.  The 
outside of the unit and water bottles may be wiped down with a soft cloth 
dampened with fresh water.  

7.  Refill unit and re-assemble per ASSEMBLY instructions.   

SUMMER STORAGE  

1.  Clean unit as outlined in Care & Maintenance section.  
2.  Discard used wick and any water in the reservoir or bottles and allow to dry 

thoroughly before storage.  Do not store with water inside reservoir or bottles. 

3.  Do not store unit in an attic or other high-temperature area.  
4.  Install new filter at beginning of season. 

Summary of Contents for 4D7 300 OAK BURL

Page 1: ...71816 4 09 READ AND SAVE THESE INSTRUCTIONS MODELS 4D7 300 OAK BURL 4D7 800 WHITE Digital control Variable Speed Automatic Humidistat Automatic Shutoff Quiet Setting for Nighttime use Easy to clean re...

Page 2: ...moving dry air through a saturated wick As air moves through the wick the water evaporates into the air leaving behind any white dust minerals or dissolved and suspended solids Because the water is e...

Page 3: ...e which hooks over a rib at the inside back of the cabinet This allows the wick to hang in the water channel see cutaway illustration for details Hang wick into cabinet as shown OPTIONAL AIR CLEANING...

Page 4: ...indicates when the unit is out of water FAN SPEED 3 Press the power button and select fan speed F1 through F9 proceeding from low to high speed NOTE When excessive condensation exists a lower speed se...

Page 5: ...outlet 2 Lift out the water bottle and the power pack 3 Carry bottle and base to cleaning basin Lift wick from the base allowing the water to drain Rinse wick under fresh water only Do not use soap d...

Page 6: ...IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS EXPRESS OR IMPLIED ARISING BY OPERATION OF LAW OR OTHERWISE INCLUDING WITHOUT LIMITATION MERCHANTABILITY AND OR FITNESS FOR A PARTICULAR...

Page 7: ...onamiento silencioso para uso nocturno F cil de limpiar unidad de fuerza removible CUIDE EL MEDIOAMBIENTE RECICLE LOS MATERIALES APROPIADOS Patentes 5 037 583 5 110 511 5 133 904 Otras patentes pendie...

Page 8: ...Estas soluciones pueden provocarle serios da os el ctricos al humidificador INTRODUCCI N Su humidificador vaporizador Essick Air agrega una humedad invisible a su hogar moviendo el aire seco que entr...

Page 9: ...aci n del corte transversal Colgar el filtro mecha dentro del gabinete como se muestra FILTRO DE LIMPIEZA DE AIRE OPCIONAL vendido por separado 7 Si est disponible instalar el filtro de AirCare 1051 e...

Page 10: ...n la unidad mejora su eficiencia y el desempe o 2 El controlador digital tiene una pantalla que brinda informaci n sobre el estado de la unidad Pulsar el bot n de encendido y seleccionar la velocidad...

Page 11: ...r la unidad completamente fuera y desenchufarlo de la toma de corriente 2 Levantar y sacar las botellas de agua y la unidad de fuerza 3 Llevar la botella y la base para la limpieza en la pileta Levant...

Page 12: ...MAYOR ALCANCE PERMITIDO POR LEY EXCLUYE Y REEMPLAZA TODA OTRA GARANT A Y CONDICIONES EXPRESAS O IMPL CITAS QUE SURJAN DE ALG N PROCESO LEGAL O DE OTRO ORIGEN INCLUYENDO ENTRE OTRAS LA COMERCIABILIDAD...

Page 13: ...00 BLANC Commande num rique vitesse variable Hygrostat automatique Arr t automatique Mode silencieux pour la nuit Facile n ttoyer bloc d alimentation amovible PENSEZ L ENVIRONNEMENT RECYCLEZ LES MATI...

Page 14: ...graves de l humidificateur INTRODUCTION L humidificateur vaporateur d Essick Air ajoute une humidit invisible dans la maison en faisant passer de l air sec travers un filtre m che satur d eau Au fur...

Page 15: ...un des quatre orifices situ s aux quatre coins de la base de l humidificateur Les roulettes doivent bien s ajuster et tre enfonc es jusqu ce que l paule de la tige atteigne la surface du bo tier 5 Ret...

Page 16: ...ur le r cipient par un trop plein d eau Ceci risque d endommager le r cipient de fa on ce qu il ne se vide plus correctement NOTA Lors du premier remplissage le r servoir prendra environ 20 minutes se...

Page 17: ...uement charg haut rendement qui capte les poussi res le pollen et les particules dans l air La deuxi me tape est assur e par un m dia au charbon actif qui absorbe les odeurs provenant de la cuisson de...

Page 18: ...e d sinfecter D SINFECTION DE L APPAREIL 6 Remplissez de moiti le r servoir et le r cipient avec de l eau et rajoutez 1c th d eau de javel dans chaque contenant Essuyez le bo tier et l ext rieur des r...

Page 19: ...EST EN LIEU ET PLACE ET EXCLUT TOUTES LES AUTRES GARANTIES ET CONDITIONS EXPRESS OU IMPLIQU ES D COULANT DE L EFFET DE LA LOI OU AUTREMENT Y COMPRIS SANS LIMITATION LA VALEUR COMMERCIALE ET OU L AD QU...

Reviews: