Quest 215 Dual

Quest Dry

Quest 506

Installation, Operation and Maintenance Instructions

This manual is provided to acquaint you with the 

dehumidifier so that installation, operation and 

maintenance can proceed successfully. Ultimate 

satisfaction depends on the quality of installation and a 

thorough understanding of this equipment. The dehumidifier 

is built around tested engineering principles and has passed 

a thorough inspection for quality of workmanship and 

function.

Installation, Operation and Maintenance Instructions

4201 Lien Rd 

Madison, WI 53704 

Toll-Free 1-877-420-1330

www.QuestHydro.com [email protected] 

– Read and Save These Instructions –

Specifications subject to change without notice.

1

Features:
•  Industry-leading efficiency, most efficient on the market 

today

•  Patented, refrigeration system
•  High-efficiency, long-life impeller fan
•  Quiet operation
•  Superior air filtration (MERV-13 standard)
•  Auto-restart after power outages
•  Environmentally friendly R410A refrigerant
•  Low voltage control

TS-1016

10/17 Rev. A

Water Removal Rates (Pints/Day) @ 80°F 60% (AHAM)

 

 

Dehumidifier 

Pints Removed  Gallons/Liters

 

Quest 506 

506 

63.2/239.4

PATENT PENDING

Summary of Contents for 506

Page 1: ...nstallation Operation and Maintenance Instructions 4201 Lien Rd Madison WI 53704 Toll Free 1 877 420 1330 www QuestHydro com info QuestHydro com Read and Save These Instructions Specifications subject...

Page 2: ...tions 4 4 Installation 5 4 1 Location 5 4 2 Electrical Requirements 5 4 3 Condensate Removal 5 4 4 Hanging 6 5 Controls 7 5 1 Humidity Control 7 5 2 24VAC Wiring 7 5 2A Deh 3000R 8 5 2B Honeywell Remo...

Page 3: ...r table DO NOT place the device directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain pan MUST be placed under the unit if installe...

Page 4: ...and air infiltration problems should be addressed or noted in calculations 2 Registrations The Quest 506 Dehumidifier units conform to unified standard UL 60335 2 40 3 Specifications 80 F 60 RH Unit...

Page 5: ...conditions are listed on page 4 A ground fault interrupter protected circuit is required Install the remote control panel in a central area of the structure where it will sense the relative humidity...

Page 6: ...the installation Check the supporting structure to be used to verify that it has sufficient load carrying capacity to support the weight of the unit Suspend the unit only from the threaded nut retaine...

Page 7: ...nect before beginning installation 5 2 24VAC Wiring The terminal block circuit breaker and power switch are located on the intake side of the unit FLOAT External low voltage float switch Use a normall...

Page 8: ...t could become clogged and require disassembly to clean Filter non compliance invalidates the product warranty 24VAC COMP FAN HONEYWELL REMOTE HUMIDISTAT WIRING DIAGRAM QUEST DEH 3000R CONTROL WIRING...

Page 9: ...ar to an air conditioner s to remove heat and moisture from incoming air and add heat to the air that is discharged Hot high pressure refrigerant gas is routed from the compressor to the condenser coi...

Page 10: ...28 BLU WHT 19 BRN BRN 29 BLK GRN RH PROG AUX TEMP EVAP FLOAT THERMISTOR PROBE CONTROL BOARD SERIAL 3A BREAKER XFMR COM COM COMPRESSOR CONTACTOR CORD INPUT POWER BLU 6 GRN 4 YEL 5 RED 3 ORG 7 BLK 8 DE...

Page 11: ...04 COIL EVAP Item Part No Description 15 4037704 02 COIL CONDENSER 16 4037707 TXV 3 TON 17 4037708 FAN MOTORIZED IMPELLER 18 4037728 CORD 19 4038135 HANDLE POCKET 20 4038136 BEZEL HANDLE 21 4038178 WI...

Page 12: ...user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or i...

Reviews: