Quest Engineering 506 Installation, Operation And Maintenance Manual Download Page 3

1-877-420-1330

 

Quest 506 

Installation, Operation and Maintenance Instructions

3

www.QuestHydro.com

[email protected]

Safety Precautions

Read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper 

adherence to these instructions is essential to obtain maximum benefit from your 

Quest 506 Dehumidifier.

 

READ AND SAVE THESE INSTRUCTIONS

 

•  The device is designed to be installed INDOORS IN A SPACE THAT IS 

PROTECTED FROM RAIN AND FLOODING. 

•  Install the unit with space to access side panels for maintenance and 

service. DO NOT INSTALL UNIT WITH THE SERVICE PANELS 

INACCESSIBLE. 

•  Avoid directing the discharge air at people, or over the water in pool areas. 
•  If used near a pool, spa or water; be certain there is NO chance the unit 

could fall into the water, be splashed and that it is plugged into an outlet 

that is a GROUND FAULT INTERRUPT protected circuit. 

•  DO NOT use the device as a bench or table.

 

•  DO NOT place the device directly on structural members. Provide 

vibration isolation in order to minimize operational vibration and/or noise.

•  A drain pan MUST be placed under the unit if installed above a living area 

or above an area where water leakage could cause damage

•  Never operate a unit with a damaged power cord.  If the power cord is 

damaged it must be replaced by the manufacturer, its service agent, or 

similarly qualified person in order to avoid a hazard.

•  Make all electrical connections in accordance with the current edition of 

the NEC ANSI/NFPA 70 and any national and local codes or ordinances 

that may apply.

•  Do not obstruct the air intake and exhaust.  Maintain a 4ft clearance 

around the air intake and exhaust.

•  This appliance is not intended for use by persons (including children) with 

reduced physical, sensory or mental capabilities, or lack of experience 

and knowledge, unless they have been given supervision or instruction 

concerning use of the appliance by a person responsible for their safety. 

Children should be supervised to ensure that they do not play with the 

appliance.

•  Not intended for use at altitudes over 2000m.

Summary of Contents for 506

Page 1: ...nstallation Operation and Maintenance Instructions 4201 Lien Rd Madison WI 53704 Toll Free 1 877 420 1330 www QuestHydro com info QuestHydro com Read and Save These Instructions Specifications subject...

Page 2: ...tions 4 4 Installation 5 4 1 Location 5 4 2 Electrical Requirements 5 4 3 Condensate Removal 5 4 4 Hanging 6 5 Controls 7 5 1 Humidity Control 7 5 2 24VAC Wiring 7 5 2A Deh 3000R 8 5 2B Honeywell Remo...

Page 3: ...r table DO NOT place the device directly on structural members Provide vibration isolation in order to minimize operational vibration and or noise A drain pan MUST be placed under the unit if installe...

Page 4: ...and air infiltration problems should be addressed or noted in calculations 2 Registrations The Quest 506 Dehumidifier units conform to unified standard UL 60335 2 40 3 Specifications 80 F 60 RH Unit...

Page 5: ...conditions are listed on page 4 A ground fault interrupter protected circuit is required Install the remote control panel in a central area of the structure where it will sense the relative humidity...

Page 6: ...the installation Check the supporting structure to be used to verify that it has sufficient load carrying capacity to support the weight of the unit Suspend the unit only from the threaded nut retaine...

Page 7: ...nect before beginning installation 5 2 24VAC Wiring The terminal block circuit breaker and power switch are located on the intake side of the unit FLOAT External low voltage float switch Use a normall...

Page 8: ...t could become clogged and require disassembly to clean Filter non compliance invalidates the product warranty 24VAC COMP FAN HONEYWELL REMOTE HUMIDISTAT WIRING DIAGRAM QUEST DEH 3000R CONTROL WIRING...

Page 9: ...ar to an air conditioner s to remove heat and moisture from incoming air and add heat to the air that is discharged Hot high pressure refrigerant gas is routed from the compressor to the condenser coi...

Page 10: ...28 BLU WHT 19 BRN BRN 29 BLK GRN RH PROG AUX TEMP EVAP FLOAT THERMISTOR PROBE CONTROL BOARD SERIAL 3A BREAKER XFMR COM COM COMPRESSOR CONTACTOR CORD INPUT POWER BLU 6 GRN 4 YEL 5 RED 3 ORG 7 BLK 8 DE...

Page 11: ...04 COIL EVAP Item Part No Description 15 4037704 02 COIL CONDENSER 16 4037707 TXV 3 TON 17 4037708 FAN MOTORIZED IMPELLER 18 4037728 CORD 19 4038135 HANDLE POCKET 20 4038136 BEZEL HANDLE 21 4038178 WI...

Page 12: ...user is responsible for normal care This warranty does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or i...

Reviews: