background image

Fan

Speed

Humidity

Control

Power

 

 

CAUTION: 

 When filling, be careful not to pressurize the bottle by overfilling it.  Bottle 

damage can result from this, and will not drain properly. 

NOTE: 

On initial fill up, it will take approximately 20 minutes for the reservoir to fill because 

the dry wick has to absorb water. Subsequent fillings will take approximately 12 minutes, 
since the wick is already saturated. 
10.  After the filling process is complete, place the chassis/power pack unit into the cabinet, 

so it fits without tipping or rocking.

 

11.  Insert the water bottles into the humidifier, placing them with the valve cap end down, so 

that the groove in the water bottle faces the inside. 

 

12.  Replace the water bottle cover.

 

 

CONTROLS AND OPERATION 

1.  Plug cord into wall receptacle. Your humidifier is now ready for use.  The humidifier 

should not be near any heat registers. Place the unit at least FOUR inches away from 
any walls. Unrestricted airflow into the unit will result in the best efficiency and 
performance.  

2.  The digital controller has a display that provides information on the status of the unit. 

Depending on which function is being accessed, it displays relative humidity, fan speed, set 
humidity and indicates when the unit is out of water.  

FAN SPEED 

3. Press the power button and select fan speed: F1 

through F9 proceeding from low to high speed. 

 

NOTE:  

When excessive condensation exists, a lower 

speed setting is recommended. 

HUMIDITY CONTROL 

NOTE: 

Both models have an automatic humidistat that 

cycles the humidifier on and off as required to maintain 
the selected setting.  
4. At initial startup the relative humidity of the room will 

be displayed. 

5. Each successive push of the Humidity Control Button 

will increase the setting in 5% increments. At 65% set 
point, the unit will operate continuously.  

6.  One bottle is designed to empty first. The control 

display will indicate each bottle empties with a flashing “F”.  When the unit is 
completely out of water, the motor will shut off.  

7.  This humidifier has a check filter reminder timed  to appear after 720 hours of operation. 

When the Check Filter (CF) message is displayed, disconnect the power cord and check the 
condition of the filter. The CF function is reset after plugging the unit back  in. 

OPTIONAL AIRCARE® FILTER 

The optional Aircare® filter is an excellent means of cleaning the air while using your 
humidifier. The first stage of the air filter is a high-efficiency, electro-statically charged filter 
media which traps dust, pollen, and airborne pollutants. The second stage is an activated 
carbon media which absorbs odors from cooking, pets, or tobacco smoke.  
 

Summary of Contents for 4D7 300 OAK BURL

Page 1: ...71816 4 09 READ AND SAVE THESE INSTRUCTIONS MODELS 4D7 300 OAK BURL 4D7 800 WHITE Digital control Variable Speed Automatic Humidistat Automatic Shutoff Quiet Setting for Nighttime use Easy to clean re...

Page 2: ...moving dry air through a saturated wick As air moves through the wick the water evaporates into the air leaving behind any white dust minerals or dissolved and suspended solids Because the water is e...

Page 3: ...e which hooks over a rib at the inside back of the cabinet This allows the wick to hang in the water channel see cutaway illustration for details Hang wick into cabinet as shown OPTIONAL AIR CLEANING...

Page 4: ...indicates when the unit is out of water FAN SPEED 3 Press the power button and select fan speed F1 through F9 proceeding from low to high speed NOTE When excessive condensation exists a lower speed se...

Page 5: ...outlet 2 Lift out the water bottle and the power pack 3 Carry bottle and base to cleaning basin Lift wick from the base allowing the water to drain Rinse wick under fresh water only Do not use soap d...

Page 6: ...IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES AND CONDITIONS EXPRESS OR IMPLIED ARISING BY OPERATION OF LAW OR OTHERWISE INCLUDING WITHOUT LIMITATION MERCHANTABILITY AND OR FITNESS FOR A PARTICULAR...

Page 7: ...onamiento silencioso para uso nocturno F cil de limpiar unidad de fuerza removible CUIDE EL MEDIOAMBIENTE RECICLE LOS MATERIALES APROPIADOS Patentes 5 037 583 5 110 511 5 133 904 Otras patentes pendie...

Page 8: ...Estas soluciones pueden provocarle serios da os el ctricos al humidificador INTRODUCCI N Su humidificador vaporizador Essick Air agrega una humedad invisible a su hogar moviendo el aire seco que entr...

Page 9: ...aci n del corte transversal Colgar el filtro mecha dentro del gabinete como se muestra FILTRO DE LIMPIEZA DE AIRE OPCIONAL vendido por separado 7 Si est disponible instalar el filtro de AirCare 1051 e...

Page 10: ...n la unidad mejora su eficiencia y el desempe o 2 El controlador digital tiene una pantalla que brinda informaci n sobre el estado de la unidad Pulsar el bot n de encendido y seleccionar la velocidad...

Page 11: ...r la unidad completamente fuera y desenchufarlo de la toma de corriente 2 Levantar y sacar las botellas de agua y la unidad de fuerza 3 Llevar la botella y la base para la limpieza en la pileta Levant...

Page 12: ...MAYOR ALCANCE PERMITIDO POR LEY EXCLUYE Y REEMPLAZA TODA OTRA GARANT A Y CONDICIONES EXPRESAS O IMPL CITAS QUE SURJAN DE ALG N PROCESO LEGAL O DE OTRO ORIGEN INCLUYENDO ENTRE OTRAS LA COMERCIABILIDAD...

Page 13: ...00 BLANC Commande num rique vitesse variable Hygrostat automatique Arr t automatique Mode silencieux pour la nuit Facile n ttoyer bloc d alimentation amovible PENSEZ L ENVIRONNEMENT RECYCLEZ LES MATI...

Page 14: ...graves de l humidificateur INTRODUCTION L humidificateur vaporateur d Essick Air ajoute une humidit invisible dans la maison en faisant passer de l air sec travers un filtre m che satur d eau Au fur...

Page 15: ...un des quatre orifices situ s aux quatre coins de la base de l humidificateur Les roulettes doivent bien s ajuster et tre enfonc es jusqu ce que l paule de la tige atteigne la surface du bo tier 5 Ret...

Page 16: ...ur le r cipient par un trop plein d eau Ceci risque d endommager le r cipient de fa on ce qu il ne se vide plus correctement NOTA Lors du premier remplissage le r servoir prendra environ 20 minutes se...

Page 17: ...uement charg haut rendement qui capte les poussi res le pollen et les particules dans l air La deuxi me tape est assur e par un m dia au charbon actif qui absorbe les odeurs provenant de la cuisson de...

Page 18: ...e d sinfecter D SINFECTION DE L APPAREIL 6 Remplissez de moiti le r servoir et le r cipient avec de l eau et rajoutez 1c th d eau de javel dans chaque contenant Essuyez le bo tier et l ext rieur des r...

Page 19: ...EST EN LIEU ET PLACE ET EXCLUT TOUTES LES AUTRES GARANTIES ET CONDITIONS EXPRESS OU IMPLIQU ES D COULANT DE L EFFET DE LA LOI OU AUTREMENT Y COMPRIS SANS LIMITATION LA VALEUR COMMERCIALE ET OU L AD QU...

Reviews: