background image

20L DEHUMIDIFIER

MODEL NO: 

SDH20.V5

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, 

and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

SDH20.V5     Issue 1     07/04/21

Original Language Version

© Jack Sealey Limited

Refer to

instructions

Indoor use only

1.  SAFETY

1.1. 

  

ELECTRICAL SAFETY

 

‰

   WARNING!

 It is the user’s

 

responsibility to check the following:

 

Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all  

 

electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

 

products. You may obtain an RCD by contacting your local Sealey stockist. 

 

If the dehumidifier is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable    

 

Appliance Test) tested.

 

Electrical safety information, it is important that the following information is read and understood.

1.1.1.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

Important

: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct  

 

fuse - see fuse rating in these instructions.

 

8

   DO  NOT

 pull or carry the appliance by the power cable.

 

8

  

DO NOT

 pull the plug from the socket by the cable. 

 

8

   DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or  

  replaced immediately by a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

        

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

         

Ensure that repairs are carried out by a qualified electrician.

        

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b) Connect the BROWN live wire to the live terminal ‘L’.

 

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

       

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

       

Sealey recommend that repairs are carried out by a qualified electrician. 

1.2. 

  

GENERAL SAFETY

 

9

   Check that the dehumidifier is in sound condition and good working order. Take immediate action to repair or replace damaged parts.

 

9

   Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

9

   Appliances shall be installed, operated and stored in a room with a working space of 

 

NOTE: 

The unit is filled with R290.

 

8

  

DO NOT

 perforate any of the components in the refrigerant circuit. Refrigerant gas may be odourless.

 

8

  

DO NOT

 attempt any repairs or maintenance unless suitably qualified.

 

8

  

DO NOT

 stand or place any object within 10cm from the front of the unit, 20cm from the rear and sides of the unit, and 30cm above  

  the unit.

 

8

  

DO NOT

 obstruct the air intakes or outlets of the dehumidifier.

 

8

  

DO NOT 

cover the unit.

 

8

  

DO NOT

 get wet. 

 

8

  

DO NOT

 place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.

 

8

  

DO NOT

 operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO NOT

 switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the “OFF” position first.

 

8

  

DO NOT

 remove the float lever from the water collection tank.

 

8

  

DO NOT

 connect or disconnect the plug from the mains with wet hands.

 

8

  

DO NOT 

use an extension lead.

 

9

   Unplug before moving.

 

9

   Place on flat level ground which can hold dehumidifier and full water tank weight

 

9

   Always discard the water from the collection tank, 

DO NOT

 use it for any other purpose.

 

9

   To prevent water from freezing, do not use the dehumidifier at ambient temperatures below 0°C.

 

8

  

DO NOT

 use the dehumidifier outside. 

 

9

   When using continuous draining, make sure that the drain hose is positioned correctly.

 

9

   Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.

 

9

   Before attempting to move the dehumidifier, empty the contents of the collection tank. Use top carrying handle when moving unit. 

Recommended fuse rating

10 Amp

Caution: 

Risk of fire

Do not cover

Summary of Contents for SDH20.V5

Page 1: ...Replace a damaged plug with a BS1363 A 13 Amp 3 pin plug If in doubt contact a qualified electrician a Connect the GREEN YELLOW earth wire to the earth terminal E b Connect the BROWN live wire to the live terminal L c Connect the BLUE neutral wire to the neutral terminal N Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight Sealey recommend that re...

Page 2: ...noeuvred 3 SPECIFICATION Model no SDH20 V5 Power Max Rated 420 320W Supply 230V Dehumidifying capacity 20L day 30o C RH 80 Maximum airflow 195m hr Refrigerant R290 Mass 60g Condensate tank 6 5L with Auto Shut Off Steaming Pressure Max 1 2MPa Working Temperature 5 32o C Freezing Pressure Max 2 5MPa IP Rating IPX0 Working Space 30m2 4 OPERATION 4 1 SITING REQUIREMENTS 4 1 1 Make sure there is at lea...

Page 3: ...4 1 The filter needs to be cleaned every two weeks for effective operation of the dehumidifier 4 14 2 Remove the plug from the mains supply 4 14 3 Place finger into the recess on the bottom edge of the filter cover and lift up and remove to allow filter to be removed 4 14 4 DO NOT use any liquid to wash the filter Only dry in direct sunlight It is recommenced to replace the filter every six months...

Page 4: ...fluids according to local regulations WEEE REGULATIONS Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment WEEE When the product is no longer required it must be disposed of in an environmentally protective way Contact your local solid waste authority for recycling information Note It is our policy to continually i...

Reviews: