4.2.1.
With keypad off or unplugged, install jumper as shown in figure 1.
4.2.2.
Apply power to keypad, through the reader.
4.2.3.
There will be 4 audible beeps, from the keypad, along with the both the red &
green LEDs on the keypad flashing at the same rate.
4.2.4.
On the keypad, enter the desired site code, 0 to 255, & press # to enter, factory
default is 0.
4.2.5.
The keypad will respond with 4 rapid beeps & not accept any more entries.
4.2.6.
If the incorrect key is pressed during this sequence, pressing the * key will clear
the entry. Two rapid beeps & both LEDs will flash.
4.2.7.
The keypad will generate an error tone if the entered site code is greater than 255.
4.2.8.
Disconnect power from the keypad, & remove the jumper indicated in figure 1
above.
4.2.9.
The keypad will now generate a site code as part of the 26-bit Wiegand sequence
sent by the keypad.