RII113-A-201222.docx
Page 11 of 15
5.1.1.
Splice the supplied, 12 inch long, reader harness into the cable connected to the
control panel, using the wiring list above for the signals. It is recommended that
18 awg stranded multi-conductor cable be used to connect the reader to the panel,
at least 6 wires will be required for most panels.
5.1.2.
It is suggested that in addition to the standard red, black, white, green, & brown
signals used, but that also tan be connected to the local facility earth connection,
to avoid damaging static discharge events. Optional connections for tamper, 2
nd
LED control, & beeper control are at the integrator/installer discretion.
5.1.2.1.
For Tamper detection: Connect the blue wire to the control panel to indicate to
the panel that the reader has been removed from its’ mounting. On the back of
the reader, there is an IR sensor with a target mounted opposite to the wall,
within approximately 5mm of the sensor.
5.1.2.2.
For 2
nd
LED Control: Connect gray wire to the control panel 2
nd
LED control to
indicate amber LEDs as a secondary indication on the reader. This will not
affect any other condition in the reader, other than LED color.
5.1.2.3.
For audio control: Connect the violet wire to the control panel audio control or
other output so when this line is grounded the reader audio will sound.
5.1.2.4.
Connect the yellow wire, only if an 8-bit keypad is installed, to control the red
LED on the keypad, grounding will illuminate the red LED. In this case the
brown wire will also illuminate the green LED, when grounded. See paragraph
4.2 to toggle these LEDs, rather than control them separately.
5.1.3.
The supplied four inch long harness, as well as the keypad mounting hardware,
with the keypad will not be required for this installation.
5.2.
Mounting;