background image

Page 8 

G500-G525-I02-070214 

COMMISSIONING  THE STOVE 

 

 

The stove is fitted with a pilot light, pulse spark ignition and flame-sensing device. 

 

The control knob is located behind the right-hand foot of the stove. 

 

The pilot light is centrally located. 

 

Should the stove be extinguished for any reason wait 3 minutes before attempting 
re-ignition. 

 

Connect a suitable pressure gauge to the pressure test point. 

 

Fit AA battery to spark generator as shown below 

 

 

Fig 6 – Battery Compartment 
 

 

 

1.

 

Unscrew battery cover to fit battery. 

2.

 

Replace battery  

3.

 

Refit battery cover. 

Lighting the Pilot 

Depress  control  knob  fully.  Whilst  depressed  turn  knob  slowly  through  80°  anti-
clockwise  to 

PILOT

  setting.  Continue  to  depress  the  control  knob,  the  pulse  spark 

ignitor  should  be  heard  and  the  pilot  should  light.  Repeat  until  pilot  is  visibly  lit.    If 
necessary, the operation of the spark can be viewed by temporarily opening the front 
door. 
 
Keep knob depressed at this point for 10-15 seconds and release the knob. The pilot 
light will remain lit. 

 

Summary of Contents for G500

Page 1: ...IRED STOVE INSTALLATION USER SERVICING INSTRUCTIONS TO BE LEFT WITH THE CUSTOMER UK IRELAND G500 G525 For use in UK Ireland on Natural gas at a supply pressure of 20mbar or Propane at a supply pressure of 37mbar GB IE ...

Page 2: ...ust be removed or fixed permanently in the fully open position or shall only be fitted in accordance with National Regulations If the chimney has previously been used to burn solid fuel the chimney should be swept before the stove is installed Before the stove is installed a flue test in accordance with National Regulations should be carried out The gas connection must be in accordance with Nation...

Page 3: ...W SUPPLY PRESSURE 20 mbar 25 mbar INJECTOR SIZE 82 320 82 320 GAS CONNECTION 8mm O D Tube 8mm O D Tube COUNTRIES OF DESTINATION CH CZ ES FI GB IE IT PT SE NL LPG Settings G500 G525 GAS GATEGORY I3P HEAT INPUT NETT HIGH LOW 4 23kW 1 96kW SUPPLY PRESSURE 37 mbar INJECTOR SIZE 92 130 GAS CONNECTION 8mm O D Tube COUNTRIES OF DESTINATION CH CZ ES FR GB IE PT ...

Page 4: ...Page 4 G500 G525 I02 070214 DIMENSIONS AND CLEARANCES Fig 1a G525 Dimensions Fig 1b G500 Dimensions Optional rear flue attachment available from www esseparts com ...

Page 5: ...t a fire surround should not be closer than 400mm from the stove if manufactured from a combustible material A combustible shelf may be fitted provided that it is not more than 150mm deep and there is at least 400mm clearance from the top of the stove Coal Arrangement The coals logs should only be arranged as shown in the layout given in the Installation Instructions by a qualified person The stov...

Page 6: ...er to I S813 issued by the National Standards Authority of Ireland Gas Connection The gas supply connection is at the right hand side of the stove on the gas valve A nut and olive strapped to the valve body tail pipe and a pressure test elbow are supplied with the stove for easy connection The gas supply should incorporate a service tap be purged and any loose matter removed Connect the gas supply...

Page 7: ...Page 7 G500 G525 I02 070214 Positioning the Coals Under no circumstances should the stove be operated with the door open without the door attached or the glass in the door damaged broken or missing ...

Page 8: ...battery to spark generator as shown below Fig 6 Battery Compartment 1 Unscrew battery cover to fit battery 2 Replace battery 3 Refit battery cover Lighting the Pilot Depress control knob fully Whilst depressed turn knob slowly through 80 anti clockwise to PILOT setting Continue to depress the control knob the pulse spark ignitor should be heard and the pilot should light Repeat until pilot is visi...

Page 9: ... From any heat setting depress control knob fully and turn clockwise to PILOT position Disconnect the pressure gauge replace the test point sealing screw and test for gas soundness Turning the Pilot OFF From any heat setting or the PILOT position depress control knob fully and turn clockwise to OFF position Fig 7 G500 G525 Contemporary C series control knob CHECK FOR SPILLAGE Close all doors and w...

Page 10: ...dly shuts off the stove it should be switched off and a specialist consulted Advise that if the fire goes out for any reason wait at least three minutes before re lighting Advise the customer that the stove should not be used at a lower setting than the LOW position Advise the customer that due to the newness of materials the stove may give off a slight smell for a period of time after commissioni...

Page 11: ... be in accordance with National Regulations and must be carried out by a qualified installer Under no circumstances should the appliance be operated with the door open without the door attached or the door glass damaged broken or missing All surfaces except the control knob and battery housing are considered to be working surfaces Most parts of the stove will get hot during and after use If young ...

Page 12: ...500 G525 I02 070214 POSITIONING THE COALS The coals should only be arranged as detailed below and by a qualified person The stove must only be fitted with the ceramics supplied DO NOT use ant extra coals or logs ...

Page 13: ...y Whilst depressed turn knob slowly through 90 anti clockwise to PILOT setting Continue to depress the control knob the pulse spark ignitor should be heard and the pilot should light Repeat until pilot is visibly lit If the pulse spark generator cannot be heard the battery may need replacing see page 14 Keep knob depressed at this point for 10 15 seconds and release the knob The pilot light will r...

Page 14: ...tomatically turned off Should this occur then turn the control knob to the OFF position and wait approximately 10 minutes for the switch to automatically reset Re light the stove as described in OPERATING THE STOVE section page 13 If the stove repeatedly shuts itself off DO NOT use the stove and have the flue system checked by a qualified person This spillage monitoring system is not adjustable an...

Page 15: ... rating if ordering a new switch 1 The following servicing procedure should be carried out regularly and only by a qualified person Ensure that the fire is turned off and is cold 2 If fitted remove the screw securing the door handle and open the stove door 3 Remove the ceramics in the reverse order to that described in POSITIONING THE COALS section p 7 4 Remove and deposition of dirt lint etc care...

Page 16: ...Page 16 G500 G525 I02 070214 ESSE Engineering Limited Ouzledale Foundry Long Ing Barnoldswick Lancashire BB18 6BN Tel 01282 813 235 Fax 01282 816 876 Website and On line Store http www esse com ...

Reviews: