Page 14
G500-G525-I02-070214
Turning the Stove OFF
From any heat setting, depress control knob fully and turn clockwise to
PILOT
position.
Turning the Pilot OFF
From any heat setting or the
PILOT
position, depress control knob fully and turn
clockwise to
OFF
position.
SPILLAGE MONITORING SYSTEM
The stove is fitted with a spillage monitoring system which senses any excess
temperature due to a flue restriction or blockage. In this event the gas supply is
automatically turned off.
Should this occur then turn the control knob to the
OFF
position and wait approximately
10 minutes for the switch to automatically reset. Re-light the stove as described in
OPERATING THE STOVE section (page 13). If the stove repeatedly shuts itself off, DO
NOT use the stove and have the flue system checked by a qualified person.
This spillage monitoring system is not adjustable and must not be put out of action.
BATTERY REPLACEMENT
The battery required is a good quality AA size. This should only be replaced when the
stove is cold.
Fig 11 – Battery Compartment
1.
Unscrew battery cover to fit battery.
2.
Replace battery
3.