Page 13
G500-G525-I02-070214
Under no circumstances should the stove be operated with the door
open, without the door attached or the glass in the door damaged,
broken or missing
OPERATING THE STOVE
The stove is fitted with a pilot light, pulse spark ignition and flame-sensing device.
The control knob is located behind the right-hand foot of the stove.
The pilot light is located towards the front of the burner.
Should the stove be extinguished for any reason wait 3 minutes before re-ignition is
attempted.
The stove should not be used at a lower setting than the LOW position.
Lighting the Pilot
Depress control knob fully. Whilst depressed turn knob slowly through 90° anti-
clockwise to
PILOT
setting.
Continue to depress the control knob, the pulse spark ignitor should be heard and the
pilot should light. Repeat until pilot is visibly lit.
If the pulse spark generator cannot be heard, the battery may need replacing – see
page 14.
Keep knob depressed at this point for 10-15 seconds and release the knob. The pilot
light will remain lit.
Low Setting
If the pilot is not already lit, light the pilot as described above.
With control knob at
PILOT
setting, depress and turn anti-clockwise to
LOW
setting
and release the knob.
High Setting
If the stove is already lit on
LOW
setting, ignite stove to
LOW
setting as described
above.
Turn the control knob progressively in an anti-clockwise direction until the desired
level is achieved, up to the
HIGH
setting.