PROGRAMMING
Page 23
ADVANCED PROGRAMMING
CALL CYCLES FOR
TECHNOLOGICAL
ALARMS AND
TEST CALLS
(INST)
(cycles, from 1 to 9; 0= 10 cycles;
factory default
3
)
WAITING TIME
BETWEEN
TECHNOLOGICAL
OR TEST CALLS
TO THE SAME
NUMBER
(INST)
(minutes, from 01 to 99;
00=30 seconds, factory default
02
)
AUTOMATIC
ANSWER
(INST)
(ring number, from 1 to 9;
0= 10 rings; factory default
2
)
OPERATION
MODE AFTER
AUTOMATIC
ANSWER
(INST)
programming mode
direct connection with the car
CONNECTION
DURATION AFTER
AUTOMATIC
RESPONSE
(INST)
(minutes, from
1
to 9)
RELAY SETTING
(INST)
same behaviour as output AI
same behaviour as output AR
active for external power failure
door opener
active as long as the emergency alarm progresses
active as long as the buttons are pressed
active for telephone line absence
active for low battery
RELAY
INTERMITTENCE
(INST)
steady-state
intermittent (500 ms ON / 500 ms OFF)