background image

PROGRAMMING 

Page 21 

ADVANCED PROGRAMMING 

AUXILIARY 
ALARM 
(INST) 

 

 disabled alarm 

 enabled alarm

 

SIM CARD 
EXPIRING 
ALARM  
(INST) 

 

 disabled alarm 

 enabled alarm 

Last 
recharge 
date 

 

(dd) (mm)  

(yy) 

ENABLE FILTER 
(INST/OPER) 

 

 disabled 

 enabled

 

FILTER BYPASS 
(INST/OPER)

 

 

 (seconds, from 15 to 

30

;

 

99=no bypass) 

FILTER INPUT  
NORMALLY 
CLOSED/OPEN 
(INST/OPER) 

 

 

normally closed

 

 

normally open

 

ALARM 
OPERATION 
WITHOUT 
TELEPHONE LINE  
(INST) 

 

 AI indicator light lit and courtesy message 

 

AI indicator light unlit and no courtesy message

 

 AI indicator light lit and no courtesy message

 

REPEATS OF 
COURTESY 
MESSAGE 
DURING 
AN ALARM 
(INST)

 

 

 (seconds between two courtesy messages, from 

         02 to 59; 00=no courtesy message; 

01=one

  

         

courtesy message for each call

“COMMUNICA-
TION 
ACTIVATED” 
MESSAGE 
SETTING 
(INST) 

 

 

disabled message 

 

 enabled message

 

TWO-WAY 
COMMUNICA-
TION MODE 
DURING AN 
ALARM  
(INST) 

 

 

two-way communication established after input of  

     "Communication activation" code

 

 automatic two-way communication  

      established after messages 

 immediate and automatic two-way communication  

      (no messages)

 

Summary of Contents for Helpy GSM

Page 1: ...7IS 80466 25 05 2021 Alarm system for elevators QUICK GUIDE ...

Page 2: ...nector C Antenna cable connector D Reset pushbutton E Alarm pushbutton F SIM Card slot with front panel G Built in loudspeaker connector H Serial port for PC connection I Micro SD Card slot L RJ11 connector for local telephone M Battery compartment door N Terminal blocks O Built in microphone ...

Page 3: ... 13 MIC3 INPUT FOR CONNECTING THE MICROPHONE OF A PASSIVE SPEAKER UNIT OR A SINGLE MICROPHONE 14 NEGATIVE POLE 15 TEL LOCAL TELEPHONE 16 RL1 RELAY 5 17 RL1 RELAY 5 18 VVX OUTPUT FOR CONNECTING AN ADDITIONAL ACTIVE SPEAKER UNIT 19 VVY OUTPUT FOR CONNECTING THE PIT ACTIVE SPEAKER UNIT 20 ALZ ADDITIONAL ALARM INPUT 4 OR AUXILIARY INPUT 5 21 AIN GIVEN ALARM INDICATOR LIGHT output 0VDC 22 ARN RECEIVED ...

Page 4: ...ENTION It is not required to remove the PIN code prior to the use of the HelpyGSM The PIN code can be entered if necessary by setting parameter 282 INSTALLING THE ANTENNA Screw the antenna extension cable provided in the appropriate connector ATTENTION Position the antenna with magnetic base so that any metal surfaces do not block the signal ATTENTION In order to avoid damage never power up the ba...

Page 5: ...an be installed at max 6m distance from HelpyGSM or from another active speaker unit by using a shielded cable Note in case of connection of active speaker units the type of installation must be defined by setting parameters 63 and 73 Connect the speaker units beware of terminal polarity ACTIVE SPEAKER UNIT term blocks HELPYGSM terminal blocks VVY or VVX PASSIVE SPEAKER UNIT term blocks HELPYGSM t...

Page 6: ...ANDING FLOOR 3 Active speak unit VVX ALZ LANDING FLOOR 4 Passive speaker unit combined to the active speaker unit positioned in the landing floor 3 ALZ PROGRAMMING CODES TYPE OF INSTALLATION TO BE SET 633 730 factory Installation with independent speaker units on car top car cabin pit DEVICE SPEAKER UNIT terminal blocks PUSHBUTTON terminal blocks ROOF HelpyGSM Built in active speak unit Built in p...

Page 7: ... pushbutton It is possible to connect inside the elevator car voltage free contact pushbuttons or powered pushbuttons Connect following one of the diagrams shown below the car pushbutton Voltage free contact pushbuttons Powered pushbuttons 12 24Vdc 2 solutions ...

Page 8: ...age 8 INSTALLING Other pushbuttons It is possible to use for the pit the car top or the landing floors voltage free contact pushbuttons NO Connect following the diagram shown below the other pushbuttons ...

Page 9: ... switches on after pressing the emergency button to indicate the beginning of the alarm procedure and stays steady light until the end The RECEIVED ALARM INDICATOR LIGHT green switches on when the alarm call is answered Connect following one of the diagrams shown below the indicator lights ...

Page 10: ... one of the modes shown in the table C1 TERMINAL CONNECTED TO FILTER CONTACT TERMINAL BLOCKS 12 IN1 IN1 12 external reference IN1 external reference CONNECTING THE AUXILIARY INPUT Connect the external contact normally open to ALZ and terminals Note the ALZ input must be programmed as auxiliary input by setting parameter 55 CONNECTING THE RELAY Connect the output RL1 normally open contact to the ex...

Page 11: ...INSTALLING Page 11 WIRING DIAGRAM EXAMPLE 1 ...

Page 12: ...Page 12 INSTALLING WIRING DIAGRAM EXAMPLE 2 ...

Page 13: ... minute after power up to give time to the HelpyGSM to register correctly with the GSM network Make sure the GSM status LED flashes briefly once every 3 seconds as shown in the paragraph LED signalling GSM status on page 29 If the GSM status LED flashes quicker and stays lit for a longer time see on page 29 the HelpyGSM has not properly registered with the GSM provider or the SIM card is protected...

Page 14: ...all to check the telephone line presence dial and after the Correct message digit the telephone number to make a test call 2 TESTING THE ALARM PROCEDURE Press the emergency call button for more than 2 seconds factory value The alarm starts 3 ANSWERING THE ALARM Note the activation mode of the communication with the trapped person can be configured with the Two way communication mode during an alar...

Page 15: ...de automatic reset Hang up or press to end the alarm 3nd mode automatic reset with local acknowledgement Hang up to end the call Press the reset pushbutton to end the alarm An end of alarm call will be generated Answer by the called party Press If the reset pushbutton is not pressed within 6 hours the alarm is automatically ended Note in case it should not be possible to stop the alarm procedure r...

Page 16: ...n D in the picture at page 2 Pressing shortly Allows to interrupt an alarm call By pressing shortly you get the same result as lifting the handset of the local telephone and entering Password Pressing longer 10 seconds Allows to reset the device By pressing longer the HelpyGSM will be re started with no need to disconnect the power supply ...

Page 17: ...ASIC PROGRAMMING ACCESS TO PROGRAMMING INSTALLER or OPERATOR PASSWORD factory setting EXITING THE PROGRAMMING INSTALLER or OPERATOR PASSWORD factory setting TELEPHONE NUMBERS INST position from 01 to 12 SOURCE RECEIVER X X telephone number max 20 digits emergency call button battery alarms USER periodic automatic test call ESSE TI CLI SIM card expiring alarm SMS diagnostic alarm P100 no external p...

Page 18: ... and 1 active speaker unit connected built in active speaker unit and 2 active speaker units connected simultaneous communication between all speaker units connected Active speaker unit in the car no yes DATE INST WEEKDAY dd mm yy SUNDAY MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY SATURDAY TIME INST hhmm from 0000 to 2359 RECORD THE MESSAGES INST identification message max 25s record hang up courtesy...

Page 19: ... the call hhmm from 0000 to 2359 Enabling automatic test automatic test disabled automatic test enabled EN 81 28 2018 automatic test enabled EN 81 28 2004 Manually perform a test call PROTOCOLS IDENTIFICATION CODE INST Esse ti identification code P100 SPEAKER UNITS VOLUME INST OPER built in active speaker unit loudspeaker from 1 to 5 factory default 2 microphone from 8 to 9 factory default 8 speak...

Page 20: ... PASSWORD 0 INST old new new CHANGE OPERATOR PASSWORD 1 INST old new new EMERGENCY CALL BUTTONS DELAY INST seconds from 2 to 9 factory default 3 CAR EMERGENCY CALL BUTTON ALC NORMALLY CLOSED OPEN INST normally closed normally open NO EXTERNAL POWER SUPPLY ALARM INST disabled alarm enabled alarm with XX minutes delay from 01 to 99 SPEAKER UNITS DIAGNOSTIC ALARM INST disabled alarm enabled alarm for...

Page 21: ...ight lit and courtesy message AI indicator light unlit and no courtesy message AI indicator light lit and no courtesy message REPEATS OF COURTESY MESSAGE DURING AN ALARM INST seconds between two courtesy messages from 02 to 59 00 no courtesy message 01 one courtesy message for each call COMMUNICA TION ACTIVATED MESSAGE SETTING INST disabled message enabled message TWO WAY COMMUNICA TION MODE DURIN...

Page 22: ...om 1 to 3 digits factory default 9 EXCLUSION CODE INST from 1 to 3 digits factory default 1 RESET MESSAGES INST identification message courtesy message CHANGE LANGUAGE INST language 00 Italian 01 English 02 German 03 French 07 Spanish MULTI LANGUAGE COURTESY MESSAGE INST second language third language DURATION OF TWO WAY COMMUNICA TION DURING AN ALARM INST minutes from 2 to 9 NUMBER OF CALLS TO TH...

Page 23: ... rings factory default 2 OPERATION MODE AFTER AUTOMATIC ANSWER INST programming mode direct connection with the car CONNECTION DURATION AFTER AUTOMATIC RESPONSE INST minutes from 1 to 9 RELAY SETTING INST same behaviour as output AI same behaviour as output AR active for external power failure door opener active as long as the emergency alarm progresses active as long as the buttons are pressed ac...

Page 24: ... MCC MNC ENABLE ROAMING INST ENTER PIN CODE WHEN PIN ACTIVE INST PIN PIN ASSIGN NEW PIN INST PIN PIN DISABLE PIN REQUEST INST RESTORE PIN REQUEST INST LISTEN TO THE GSM SIGNAL LEVEL INST Digits Quality 0 no signal 1 low signal connection not guaranteed 2 medium signal 3 good signal 4 high signal LISTEN TO THE BATTERY LEVEL INST expressed in mV LISTEN TO THE POWER SUPPLY LEVEL INST expressed in mV ...

Page 25: ...ed e stant software e stant software also allows to update the firmware of the HelpyGSM customize the messages of the HelpyGSM set a micro SD card to use for programming customizing the messages and updating the firmware of the HelpyGSM e stant can be downloaded at the following link https www esse ti it download richiesta software Programming via micro SD card The micro SD card properly set allow...

Page 26: ...ogramming codes to be performed The message format must be as follows Et hg xxx c c c c Where Et hg is the start of the programming string xxx is the password string default installer password xxx 0 c c programming code The strings and programming codes must be separated by a space Refer to the related paragraphs for the programming codes NOTIFICATION MESSAGE FORMAT The format of the notification ...

Page 27: ...CONNECTED TO VVX DEACTIVATE ALL EXTERNAL CALLS TELEPHONE NUMBER DOOR OPENER RELAY Use remotely with HelpyGSM at rest Call HelpyGSM and wait for a response After listening to the elevator identification message dial password factory setting All of the programming and functions below can now be performed USE REMOTELY WITH HELPYGSM AT REST CONVERSATION WITH ONE SPEAKER UNIT CAR SPEAKER UNIT SPEAKER U...

Page 28: ...iodical test call yellow Emergency call alarm Emergency call alarm suspended Other alarms Test call LED signalling GSM signal strength green No signal Low signal level connection not guaranteed Medium signal level Good signal level High signal level ...

Page 29: ...y is connected and the battery has max capacity charge The external power supply is connected and the battery has good capacity charge The external power supply is connected and the battery has medium capacity charge The external power supply is connected and the battery has low capacity charge The external power supply is connected and the battery is either disconnected or dead The external power...

Page 30: ...e battery guarantees 1 hour operation in idle state Given alarm indicator light yellow Alarm Received alarm indicator light green Voice connection Missed test call notification EN 81 28 2018 The Given alarm indicator light and the Received alarm indicator light flash in opposition to indicate the failure of the automatic test call The flashing sequence ends after the next successful test call or e...

Page 31: ... antenna or damaged connection cable Check the antenna connection and the correct operation of the cable GSM signal absence Check the signal strength by your mobile phone Insufficient power supply Check the power supply Generic SW problem Switch off and back on HelpyGSM The GSM status LED blinks slowly but the GSM signal LED is unlit GSM signal level is too low to allow outgoing calls Move the ant...

Page 32: ...HelpyGSM edition 25 05 2021 Esse ti S r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it support esse ti it ...

Reviews: