background image

 

Page 17 

SMS

 TEXT SETTING

 

It  allows  to  customize  the  text  of  the  SMS  sent  by  the  GSM500  M2M 
when the input TEL is closed. 

Et-vm1 message (customized text) 

Command

:  message 

Parameter

:  customized text enclosed in parentheses 

    

max. 40 characters 

Default

ALARM VENDING MACHINE 

Example:  
it is required to set the following text “Alarm: escalator n.12” 
Outgoing message text: 
Et-vm1 message (Alarm: escalator n.12) 
Message text notifying accepted command:  
ET?VM1 message (Alarm: escalator n.12) 

S

ETTING TELEPHONE NUMBER FOR 

NOTIFICATIONS

 

It  allows  to  enter  the  telephone  number  appointed  for  SMS  or  CLI  
notifications when the input TEL is closed. 

Et-vm1 alertphone x…x 

Command

:  alertphone 

Parameter

:  telephone number with country code 

 

 

Summary of Contents for GSM500 M2M

Page 1: ...26 09 2017 User s manual...

Page 2: ...user The User shall be responsible for defects arising from the use of the product Esse ti shall only be responsible for defects according to and within the limitations set by the Presidential Decree...

Page 3: ...commendations 14 PROGRAMMING 15 Message format 15 Notification message format 16 SMS text setting 17 Setting telephone number for notifications 17 Notification type setting 18 Setting telephone number...

Page 4: ...EU DECLARATION OF CONFORMITY 25...

Page 5: ...ng maintenance etc Always refer to an authorized service centre for repair The device must be installed in a ventilated place making sure that the ventilation slots are never obstructed Do not install...

Page 6: ...input TEL signalling via SMS or CLI call ring Battery check model GC External power failure control model GC SMS technological alerts low battery dead battery replaced battery external power failure...

Page 7: ...put CE mark LED The GSM500 M2M is equipped with 4 outer LEDs LEDs flashing is described at chapter SIGNALS see page 22 Green LED GSM signal indicator LED Red LED Device status indicator LED White LED...

Page 8: ...panel C LED indicating signal strength green LED indicating device status red LED indicating input status white and LED indicating line status blue D 230 Vac external adapter input E TEL terminal bloc...

Page 9: ...its housing cover Lower the SIM card housing cover and shift it upward until it blocks WARNING The SIM card PIN must be DISABLED If the PIN is enabled it must be disabled through a mobile phone Inser...

Page 10: ...with magnetic base so that any metal surfaces do not block the signal Connections Connect the TEL terminal to a voltage free contact of an external device Connect the RL terminal if present and if nec...

Page 11: ...ge 8 taking care to respect the polarity Connect the backup batteries if present to the dedicated input H in the picture at page 8 Close the device cover paying attention to the power supply cable WAR...

Page 12: ...LED device status flashes briefly once every 3 seconds as shown in chapter SIGNALS see page 22 If the red LED flashes quicker and stays lit for a longer time see page 22 the GSM device has not properl...

Page 13: ...a where the signal is strong enough Note the signal strength may vary according to the telephone provider Drill two holes with 5 mm diameter on the wall at a distance of 50 mm Insert the 2 wall plugs...

Page 14: ...damage the device water humidity etc Do not install the GSM500 M2M near electronic radio or TV sets Personal Computers wired radio systems etc or magnetic credit cards etc devices that could be subjec...

Page 15: ...mat is not respected When the GSM500 M2M sends or receives an SMS the line status LED blue will turn on Message format Each programming SMS contains one or more programming commands The message format...

Page 16: ...sage format SMS notifying an accepted command ET VM1 cmd par SMS notifying a rejected command ET VM1 cmd ERROR Example outgoing SMS to set the telephone number 0039333123123123 Outgoing message text E...

Page 17: ...ING MACHINE Example it is required to set the following text Alarm escalator n 12 Outgoing message text Et vm1 message Alarm escalator n 12 Message text notifying accepted command ET VM1 message Alarm...

Page 18: ...required to set the notification via CLI call Outgoing message text Et vm1 alertmode call Message text notifying accepted command ET VM1 alertmode call SETTING TELEPHONE NUMBER FOR TECHNOLOGICAL ALERT...

Page 19: ...the programmed number with the following text message ALARM BATTERY BROKEN When the battery is reconnected or replaced if found damaged an SMS is sent to the programmed number with the following text...

Page 20: ...inutes of lack of external power supply zz from 01 to 99 minutes of restored power supply Default external power failure control disabled RELAY COMMAND It allows to command the relay via SMS only on m...

Page 21: ...elay administrator number the GSM500 M2M activate deactivate the relay for 15 seconds default or for the previously set time through the relay pulse command Et vm1 relayphone x x Command relayphone Pa...

Page 22: ...evel Device status indicator LED RED Upon switch on it indicates GSM network login in progress if it keeps blinking it may indicate that the GSM500 M2M has not been correctly registered with the netwo...

Page 23: ...HITE It indicates that the input TEL is closed It indicates that the input TEL is open Line status indicator LED BLUE It indicates that the GSM500 M2M is sending or receiving an SMS or a CLI call It i...

Page 24: ...expired or damaged Check the SIM card operation on your mobile phone SIM card not supported e g UMTS Use a GSM SIM card Make a test with a SIM card from a different GSM provider Unconnected antenna or...

Page 25: ...Page 25 EU DECLARATION OF CONFORMITY...

Page 26: ...Page 26...

Page 27: ...Page 27...

Page 28: ...GSM500 M2M 26 09 2017 Esse ti s r l Via G Capodaglio 9 62019 Recanati MC ITALY Tel 39 071 7506066 Fax 39 071 7506057 www esse ti it E mail support esse ti it...

Reviews: