Connection to the power supply
Power supply via 230Vac external adapter
Connect the external adapter to the specific input (D in the picture
at page 8.
Connect the backup batteries (if present) to the dedicated input (H
in the picture at page 8).
Close the device cover.
or
12Vdc power supply
Connect the power supply cable to the terminal (F in the picture at
page 8) taking care to respect the polarity.
Connect the backup batteries (if present) to the dedicated input (H
in the picture at page 8).
Close the device cover, paying attention to the power supply cable.
WARNING
The backup batteries, if present, may be connected only
after GSM500 M2M has been supplied.
Note:
the max voltage to be supplied to the mains terminal F
is 17 Vdc.
Note:
the min voltage required to supply the GSM500 M2M
device by the mains terminal F is 10 Vdc.
Note: a protection cut-out switch must be installed upstream
to interrupt power supply in case of fault.