8. POSSIBLE FAULTS, CAUSES AND SOLUTIONS
1) The pump does not deliver any flow.
2)
The pump does not start.
3) The motor starts and stops automatically (klixon).
4) Insufficient flow.
5)
The Pump is noisy.
1
2
3
4
5
POSSIBLE PROBLEM
SOLUTIONS
X X
Incorrect voltage
Verify the voltage specified on the nameplate and that of
the mains
X
Thermal relay tripped
Reset thermal relay
X X
Diameter of suction line smaller than
required
Correctly dimension suction line
X X
Lack of water in the hydromassage
assembly
Fill the hydromassage assembly with water
X
Incorrect pump attachment
Attach the pump correctly
X
Lack of power
Reset the fuses
X
Jets or pipes clogged
Clean them properly
X
X
Air entry trough suction line
Verify condition of connectors and gaskets of suction line
X X
Pump seized
Contact qualified personnel
9. TECHNICAL DATA
Liquid temperature: ......................... 4ºC - 50ºC
Ambient temperature: ..................... 0ºC - 40ºC
Storage temperature: ................... -10ºC - 50ºC
Ambient relative humidity, max.: ............... 95%
Motor class
I
.
Other data see Figure 2.