background image

11

POSSIBLE PROBLEMS, CAUSES AND SOLUTIONS.

6. 

PROBLEMS

CAUSES

SOLUTIONS

–  Water flow is 

insufficient

–  Recirculation of water. 

–  Maximum flow of the pump is 

small.

–  Comprobar el correcto montaje de los componentes 

y en especial la presencia de la junta.

–  Comprobar el correcto dimensionamiento de la 

bomba.

–  No air bubbles 

emerge

–  The filter (9) fitted in the hose is 

dirty and air does not pass.

–  Air passage at the front plate (6) 

is obstructed by insects or foreign 
bodies.

–  The air regulator is closed.

–  Clean the filter (9) and remove impurities. 

–  Clean and ensure that air is passing to the 

discharge pipe. 

–  When the air regulator is opened bubbles should 

emerge.

–  The pump does 

not start

–  The capillary pipe (7) is 

disconnected or has leaks.

–  There is no electricity supply to 

the installation.

–  Incorrect pressure microswitch 

operation.

–  Check that the capillary pipe (7) is correctly 

installed.

–  Wait for electricity supply to be restored. 

–  Check electrical continuity at the pressure switch by 

activating and deactivating the button.

–  The pump stops 

running

–  The pump thermal cut-out switch 

activates.

–  The motor-protection cut-out on 

the panel throws.

–  The installation’s differential 

circuitbreaker switch triggers.

–  Electrical connection failure.

–  Check that the premises is correctly ventilated and 

that air passage of the pump fan is not obstructed.

–  Check that the pump ampere rating is less than or 

equal to the cut-out trigger rating.

–  Check for insulation or shunt-off faults. 

–  Check that electrical connections are correct.

–  The pump does 

not take in 
water

–  The pump is not primed. 

–  The suction pipes are not sealed 

and the pump takes in air.

–  The suction piping is long and the 

pump is higher than the swimming 
pool level.

–  Pool water level insufficient and 

air is being taken in.

–  Fill the suction body up to the level of the suction 

connection.

– Repair leaks.

–  Bleed air from the pump.

–  A check valve without spring pressure must be 

mounted in the suction pipes to prevent water 
draining during suction.

–  Raise the water level of the pool to at least 10 cm 

above the plate.

– The motor 

protection 
switch triggers

– Condenser defective.

–  Pump blocked by obstruction of 

the turbine.

–  Check that the condenser is of the correct capacity.

–  Replace if faulty.

–  The motor shaft must rotate slightly.

–  If not, the pump must be repaired by the technical 

service centre.

–  Noise

–  Air is entering the equipment.

–  Noise from bearings. 

–  Foreign bodies in the pump.

– Stop leaks.

–  The pump must be repaired by the technical service 

centre.

–  Remove them as explained in the pump 

maintenance manual.

Instruction manual

Summary of Contents for NCC

Page 1: ...1 Manual de instrucciones 2 Instruction Manual 7 Manuel d instructions 12 Betriebsanleitung 17 Manuale di istruzioni 22 NL Instructiehandleiding 27 NCC NCR...

Page 2: ...repair Work or repairs must be carried out only by of cial technical service centres Users can only carry out the work described in this manual The manufacturer declines responsibility for any work th...

Page 3: ...g pool with approximately 15 cm of water so that it is well tensioned Place the ange 5 on the canvas seeking out the right position and making use of the lip of the protective plate 4 to position it I...

Page 4: ...between the waterline and the maximum height of the pool Use a securing staple 10 to ensure correct tting Mount the lter 9 on the end of the hose in order to prevent dirt entering Fig P Fitting the pr...

Page 5: ...d while it is running Shutting off or quickly reducing the passage of water can give rise to pressure surges that could lead to equipment breakage Leave the pump running for a few minutes and check th...

Page 6: ...h triggers Electrical connection failure Check that the premises is correctly ventilated and that air passage of the pump fan is not obstructed Check that the pump ampere rating is less than or equal...

Page 7: ...chterlichaam 4 Placa protectora Protective plate Plaque de protection Schutzplatte Targa protetrice Beschermingsplaat 5 Brida jaci n Securing ange Bride xation Flansch Brida ssaggio Bevestigings ens 6...

Page 8: ...at 7 Tubo capilar Capillary tube Tube capillarire Kapillarrohr Tubo capillare Capilaire buis 9 Filtro espuma Foam lter Filtre mousse Filter Filtro schiuma Schuim lter 10 Grapa sujecci n Securing stapl...

Page 9: ...34 Fig A Fig B Fig C Fig D A B Fig E Fig G Fig H Fig I Fig J Fig K Fig M Fig F...

Page 10: ...UCCIONE S Junta de goma Rubber gasket Joint en caoutchouc Gummidichtung Guarnizione di gomma Ubberen ring V lvulas de paso Flow valves Vannes d isolement Durchgangsventil Valvole di passagio Afsluitkl...

Page 11: ...Three phase control cabinet Coffret commande triphas e Steuerschrank mit Drehstrom Armadio manovra trifasico Driefasige bedieningskast Esquema de conexiones Wiring diagram Sch ma de branchements Scha...

Page 12: ...t of the swimming pool Partie int rieure de la piscine Inneren Beckenbereich Parte interna della piscina Gedeelte binnen het zwembad DIMENSIONES Y PESOS DIMENSIONS AND WEIGHTS DIMENSIONS ET POIDS 7 AB...

Page 13: ...38...

Page 14: ...39...

Page 15: ...anuel sont conformes La Directive 73 23 CEE Basse tension La Directive 89 336 CEE Compatibilit lectromagn tique La Norme europ enne EN 60 335 2 41 La Norme europ enne EN 55014 1 2 Sign fonction Jordi...

Reviews: