background image

EsiWelma Srl

 

URS20SL_en.doc - rev. 0 

Oxygen detectors – URS20SL 

20/10/2010 

Gas detection systems for industrial environments 

5/8

 

 

Mechanical installation 
of the optional relay 
card 

The  control  card  can  be  expanded  with  a  relay  card  inserted  into  a  dedicated 
connector  CN3  with  four  SPDT  relays  that  will  be  activated  under  the  following 
conditions:  pre-alarm,  1

st

  threshold  alarm  2

nd

  threshold  alarm  and  sensor  fail,  and 

relative LED alerts. 
To install the card, follow the instructions below: 
 
 
Step 1: 
Insert  the  connection  slot  provided 
with  the  relay  card  into  the  control 
card,  making  sure  the  flexible  tab  is 
towards the main terminal board. 
Find CN3 connector. 

 

 

 
CN3 connector 

 

Connection slot 
(flexible tab) 

 
 
 
 

 
Step 2: 
Fit  the  relay  card  snugly 
and  pull  the  flexible  tab 
of  the  connection  slot 
towards 

the 

main 

terminal board. 
 
 
 
 
 
Flexible tab 
 
 
 

 

 
 
Step 3: 
Check  the  position  of  the  card.  Make  sure 
that  all  the  card  pins  fit  into  the  CN3 
connector  and  push  slightly  upwards  to 
check that the flexible tab on the connection 
slot keeps the card in place. 
 
 
 
 
 
 
 

Step 4: 
Tick  the  check  box  with  a 
permanent 

marker 

to 

indicate  the  presence  of 
the relay card in the device 

 

 

 

IP55 

TYPE URS20SL

 

 

 

2,5 W 

Summary of Contents for Sensigas URS20SL

Page 1: ...d more in general where oxygen is stored Oxygen deficiency is an indirect measurement of the presence of other explosive or asphyxiant gases that deplete the oxygen in the air URS20SL sensors can be u...

Page 2: ...t 1 or 2 thresholds 4 20mA Output reference selection 4mA 0 O2 20mA 30 O2 0mA no alarm 10mA 1 st threshold alarm 20mA 2 nd threshold alarm by jumper selectable polarity 4 20mA output load resistor up...

Page 3: ...the excess oxygen as quickly as possible Oxygen deficiency Detection of oxygen deficiency has the purpose of indirectly detecting the presence of other gases that deplete the oxygen in the air theref...

Page 4: ...chapter In order to change the default settings switch off the power supply input the new settings at the JP2 jumper circuit or at the S1 DIP switch as shown in the diagram then power up again in part...

Page 5: ...below Step 1 Insert the connection slot provided with the relay card into the control card making sure the flexible tab is towards the main terminal board Find CN3 connector CN3 connector Connection...

Page 6: ...trical installation The sensors are factory calibrated so they normally do not require any other calibration once installed Still after installation an operational check of the sensors is recommended...

Page 7: ...ntenance return the sensor concerned to the supplier installer who in turn will send it back to the manufacturer Sensors may need to be re calibrated using the TUL40 calibration kit and the TUS40 20 h...

Page 8: ...r industrial environments 8 8 Installation data To be filled in by Installer Installer s stamp and signature Installation site Product order number Part Number Manufacturing date Installation date Rep...