Device Profile Area
Manual • Doc.-No.: C.3012.21 / Rev. 1.1 CAN-CBX-REL4
Page 90 of 99
7.10.9 Error Mode Output Bit 1 to 4 (6250
h
)
This object determines whether the relays are set to an error value defined in object 6260
h
, in case of
an internal device error indication.
Index
Sub-
index
Description
Value range
Default
Data type
Access
6250
0
number_of_entries
4
4
unsigned 8
ro
1
error_mode_Rel1
0,1
1
Boolean
rw
2
error_mode_Rel2
0,1
1
Boolean
rw
3
error_mode_Rel3
0,1
1
Boolean
rw
4
error_mode_Rel4
0,1
1
Boolean
rw
Assignment of the variable error_mode_Relx (x=1...4)
error_mode_Relx
Value
Meaning
true
1
Set the output of relay x to the error value predefined in object
6260
h
in case of an error (default)
false
0
The current state of relay x is kept if an internal device error
occurs.
(x=1...4)