1400 Indoor Outdoor Installation
Window Requirements
The window, provided by your builder or local window supplier, must meet the following specifications:
• The window framing must be adjusted to suit the cladding of the building.
• The head flashing of the window needs to comply with local building codes.
• The window must be able to be opened fully from outside to allow cleaning of the fireplace glass and maintenance of
the fuelbed. An external locking mechanism for the window is required.
• The window needs to be a standard insulated glazing unit (IGU) with an air filled gap (do not use an argon filled IGU).
Minimum Allowable Window and Window Frame Measurements:
Viewable Glass
1300mm
380mm
Aluminium Framing - interior measurement
1380mm
460mm
Construction Guide
1. Begin with framing the cavity and installing the window as per local building codes. The requirements for the
window are listed above.