630502_4
DS
1400 Indoor Outdoor Installation
2. Install the non-combustible sheet that will deflect the heat out of the cavity. This needs to be constructed as
per the architectural details on the previous pages. The width of the non-combustible sheet needs to be at least
as wide as the outside measurements of the indoor-outdoor kit (1400mm minimum).
3. Convert the fire (instructions follow) by affixing the indoor outdoor kit pieces to the fire. The way that these
pieces sit into the window is shown below without (3A) and with (3B) the fire as reference. Place the LED’s as
the following sections describe, then slide the fire into place using the instructions on the last page.
3A
3B
Indoor - Outdoor Kit Pieces